Zhodnocení rizika průvanu v obývacím pokoji s přívodem čerstvého vzduchu pomocí konvektoru
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F03%3APU42029" target="_blank" >RIV/00216305:26210/03:PU42029 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Draft assessment in a living room with supply air convector, 7th International Symposium on Ventilation for Contaminant Control
Popis výsledku v původním jazyce
Within a EU funded project RESHYVENT a new hybrid ventilation system is being developed. The ventilation system is a demand controlled passive stack assisted exhaust fan system. The outdoor air enters the apartment through living room and bedrooms. The fresh air is sucked through a supply air convector and supply air radiators respectively and air leakage through the façade. The supply air convector in the living room is equipped with a heat exchanger to preheat the entering air and with a back draft daamper and a wind damper. The outdoor air passes through the living room to the exhaust air terminal devices, which are located near the ceiling. In order to ensure good thermal comfort it is important that the supply air does not cause any draft. The present contribution deals with a sensitivity analysis that was performed using CFD modelling. The living room of a three bedroom apartment was chosen as a sample room. In total 63 variants have been solved, covering different air flow rates
Název v anglickém jazyce
Draft assessment in a living room with supply air convector, 7th International Symposium on Ventilation for Contaminant Control
Popis výsledku anglicky
Within a EU funded project RESHYVENT a new hybrid ventilation system is being developed. The ventilation system is a demand controlled passive stack assisted exhaust fan system. The outdoor air enters the apartment through living room and bedrooms. The fresh air is sucked through a supply air convector and supply air radiators respectively and air leakage through the façade. The supply air convector in the living room is equipped with a heat exchanger to preheat the entering air and with a back draft daamper and a wind damper. The outdoor air passes through the living room to the exhaust air terminal devices, which are located near the ceiling. In order to ensure good thermal comfort it is important that the supply air does not cause any draft. The present contribution deals with a sensitivity analysis that was performed using CFD modelling. The living room of a three bedroom apartment was chosen as a sample room. In total 63 variants have been solved, covering different air flow rates
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BJ - Termodynamika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Ventilation 2003
ISBN
—
ISSN
—
e-ISSN
—
Počet stran výsledku
7
Strana od-do
267-273
Název nakladatele
NEUVEDEN
Místo vydání
Sapporo
Místo konání akce
Sapporo
Datum konání akce
5. 8. 2003
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—