DRAFT RISK SIMULATION IN A ROOM WITH AIR TRANSFER DEVICE
Popis výsledku v původním jazyce
The article describes the influence of the supply air devices that are part of hybrid ventilation system which is being developed within a EU funded project RESHYVENT as a part of this project, on thermal comfort in living-room of a three-bedroom apartment. The supply air radiator and the supply air convector are compared. The fresh air is sucked through a supply air convector and supply air radiator respectively and the air leakage through the facade is assumed too. 2 variants, which cover different ouutdoor temperature and supply air temperature for each device, have been solved. The main difference between them is the direction of the incoming air. Supply air radiator is like a classical radiator, outdoor air comes through the radiator, warms up andenters the room vertically. Supply air convector is stand-alone device with heat exchanger to preheat the entering air and with a back draft damper and a wind damper. In this case the outdoor air enters the room horizontally. The CFD mode
Název v anglickém jazyce
DRAFT RISK SIMULATION IN A ROOM WITH AIR TRANSFER DEVICE
Popis výsledku anglicky
The article describes the influence of the supply air devices that are part of hybrid ventilation system which is being developed within a EU funded project RESHYVENT as a part of this project, on thermal comfort in living-room of a three-bedroom apartment. The supply air radiator and the supply air convector are compared. The fresh air is sucked through a supply air convector and supply air radiator respectively and the air leakage through the facade is assumed too. 2 variants, which cover different ouutdoor temperature and supply air temperature for each device, have been solved. The main difference between them is the direction of the incoming air. Supply air radiator is like a classical radiator, outdoor air comes through the radiator, warms up andenters the room vertically. Supply air convector is stand-alone device with heat exchanger to preheat the entering air and with a back draft damper and a wind damper. In this case the outdoor air enters the room horizontally. The CFD mode
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BJ - Termodynamika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
25th AIVC Conference - Ventilation and Retrofitting
ISBN
2-9600355-6-9
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
177-182
Název nakladatele
INIVE EEIG
Místo vydání
Brusel
Místo konání akce
Prague
Datum konání akce
15. 9. 2004
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—