Vliv parametrů fuzzy prediktoru na predikci zbytkové životnosti izolací elektrických strojů točivých
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F04%3APU48309" target="_blank" >RIV/00216305:26210/04:PU48309 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of Fuzzy Predictor Parameters on the Prediction of the Residual Lifetime of Electrical Rotary Machine Insulation
Popis výsledku v původním jazyce
The contribution deals with the lifetime prediction of the Relanex insulating material used for the electrical rotary machine windings. By means of quantities Bv, Ba, Uk and utilizing the fuzzy apparatus in the form of fuzzy predictor, we determine the intensity of breakdown voltage and, consequently, the current state of the insulating material from the point of view of electric strength and the lifetime prediction of the material. To predict the breakdown voltage intensity, the fuzzy predictor of Sugeeno type was used, particularly for easy setting of input parameters. According to the matrix of the values of individual inputs (Bv, Ba, Uk, Up) measured and the subsequent training phase, it is possible to predict the values of critical voltage Ups that can be further compared with real breakdown voltages Up and to make evaluations on the basis of relative and absolute errors.
Název v anglickém jazyce
Influence of Fuzzy Predictor Parameters on the Prediction of the Residual Lifetime of Electrical Rotary Machine Insulation
Popis výsledku anglicky
The contribution deals with the lifetime prediction of the Relanex insulating material used for the electrical rotary machine windings. By means of quantities Bv, Ba, Uk and utilizing the fuzzy apparatus in the form of fuzzy predictor, we determine the intensity of breakdown voltage and, consequently, the current state of the insulating material from the point of view of electric strength and the lifetime prediction of the material. To predict the breakdown voltage intensity, the fuzzy predictor of Sugeeno type was used, particularly for easy setting of input parameters. According to the matrix of the values of individual inputs (Bv, Ba, Uk, Up) measured and the subsequent training phase, it is possible to predict the values of critical voltage Ups that can be further compared with real breakdown voltages Up and to make evaluations on the basis of relative and absolute errors.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BF - Elementární částice a fyzika vysokých energií
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F03%2F0621" target="_blank" >GA102/03/0621: Ireverzibilní procesy v elektroizolačních materiálech pro vysoké teploty</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
APTADM 2004 International Conference on Advances in Processing, Testing and Application of Dielectric Materials
ISBN
0324-9441
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
204-207
Název nakladatele
Wroclaw (Poland)
Místo vydání
Wroclaw (Poland)
Místo konání akce
Wroclaw
Datum konání akce
15. 9. 2004
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—