Effervescent atomizer - temporal and spatial variations of spray structure
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F06%3APU62913" target="_blank" >RIV/00216305:26210/06:PU62913 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effervescent atomizer - temporal and spatial variations of spray structure
Popis výsledku v původním jazyce
An effervescent atomizer generated spray is studied using combined PIV-PLIF technique. Liquid phase concentration, 3D velocity and thus mass flux distribution in a plane perpendicular to the spray axis is measured. Spatial and temporal fluctuations of the liquid concentration and mass flux are evaluated. Both fluctuations show annular spatial distribution with low value near spray axis and maximum close to the spray edge. A transparent Plexiglass atomizer is used in this study. Internal atomizer two-phase flow patterns are predicted by published maps and actual two-phase flow structure is visualized by a digital camera. The atomizer is operated in the range of air gauge pressure 0.1 - 0.5 MPa and Gas-to-Liquid-Ratio 2 - 50%. This range of operation conditions leads to various two-phase flow patterns from bubbly to dispersed. Results show that in case of high GLR the internal mixture is relatively homogeneous and decreasing GLR under certain value can lead to a poor mixing. Influence of
Název v anglickém jazyce
Effervescent atomizer - temporal and spatial variations of spray structure
Popis výsledku anglicky
An effervescent atomizer generated spray is studied using combined PIV-PLIF technique. Liquid phase concentration, 3D velocity and thus mass flux distribution in a plane perpendicular to the spray axis is measured. Spatial and temporal fluctuations of the liquid concentration and mass flux are evaluated. Both fluctuations show annular spatial distribution with low value near spray axis and maximum close to the spray edge. A transparent Plexiglass atomizer is used in this study. Internal atomizer two-phase flow patterns are predicted by published maps and actual two-phase flow structure is visualized by a digital camera. The atomizer is operated in the range of air gauge pressure 0.1 - 0.5 MPa and Gas-to-Liquid-Ratio 2 - 50%. This range of operation conditions leads to various two-phase flow patterns from bubbly to dispersed. Results show that in case of high GLR the internal mixture is relatively homogeneous and decreasing GLR under certain value can lead to a poor mixing. Influence of
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings 10th International Congress on Liquid Atomization and Spray Systems ICLASS-2006
ISBN
4-9902774-1-4
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
—
Název nakladatele
Institute for Liquid Atomization and Spray Systems - Japan
Místo vydání
Kyoto.,Japan
Místo konání akce
Kyoto, Japan
Datum konání akce
1. 8. 2006
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—