Návrh a realizace experimentálního zařízení pro boimechanickou komponentu
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F07%3APU69922" target="_blank" >RIV/00216305:26210/07:PU69922 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Design and Realization of Experimental Device for Particular Biomechanics
Popis výsledku v původním jazyce
The contribution deals with the testing of selected biomechanical components, total hip joint endoprosthesis and cervival fixators in particular. The device for testing the cervival fixators is designed and build. Currently we focus on mutual correctionof motion. The motion on the experimental device is realized using stepper motors. Actuators are formed as stepper motors with gear. Using coupling those are connected to the coiling bowls which swing under the influence of brought torque and thus inducegiven load (inflexion). Another type of load of spine fixator is torsion, which is again induced using the stepper motor. The test element is made of two cervival vertebrae with intervertebral disk between. The test element is then bathed into the dentacryl and after curing it is put into the test machine bowls where it is fixed using screws. Test elements prepared this way is ready for the test. Test experiment was performed on the test device with the aim to determine the functionalit
Název v anglickém jazyce
Design and Realization of Experimental Device for Particular Biomechanics
Popis výsledku anglicky
The contribution deals with the testing of selected biomechanical components, total hip joint endoprosthesis and cervival fixators in particular. The device for testing the cervival fixators is designed and build. Currently we focus on mutual correctionof motion. The motion on the experimental device is realized using stepper motors. Actuators are formed as stepper motors with gear. Using coupling those are connected to the coiling bowls which swing under the influence of brought torque and thus inducegiven load (inflexion). Another type of load of spine fixator is torsion, which is again induced using the stepper motor. The test element is made of two cervival vertebrae with intervertebral disk between. The test element is then bathed into the dentacryl and after curing it is put into the test machine bowls where it is fixed using screws. Test elements prepared this way is ready for the test. Test experiment was performed on the test device with the aim to determine the functionalit
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JR - Ostatní strojírenství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Program and Abstracts
ISBN
978-81-904262-8-2
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
1-4
Název nakladatele
Biomedical Enginering Society
Místo vydání
Singapore
Místo konání akce
Bangkok
Datum konání akce
9. 7. 2007
Typ akce podle státní příslušnosti
WRD - Celosvětová akce