NAPĚŤOVÁ ANALÝZA CHLADIČE PÁRY
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F08%3APU75477" target="_blank" >RIV/00216305:26210/08:PU75477 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
STRESS ANALYSIS OF SUPERHEAT STEAM COOLER
Popis výsledku v původním jazyce
Power plants use special superheat steam coolers for cooling the superheat steam before it enters turbines. Superheat steam coolers lower the steam temperature within the range of few degrees. Purpose of this equipment is to maintain a steam of desired quality and to keep the temperature under creep area. Certain environment does not allow 5 C temperature raise and the coolers have to obey that. Nozzle is connected to the centre of the main pipe and distributive ring is at the end of the nozzle. Its purpose is to evenly distribute cooling water into the superheat steam. Nozzle of the main pipe should not interfere with thermal dilatation. Conical diffuser is in front of the torus in the pipe and it serves for lowering head loss. Diffuser is connected to a shutter which protects the main pipe against cooling water drops.
Název v anglickém jazyce
STRESS ANALYSIS OF SUPERHEAT STEAM COOLER
Popis výsledku anglicky
Power plants use special superheat steam coolers for cooling the superheat steam before it enters turbines. Superheat steam coolers lower the steam temperature within the range of few degrees. Purpose of this equipment is to maintain a steam of desired quality and to keep the temperature under creep area. Certain environment does not allow 5 C temperature raise and the coolers have to obey that. Nozzle is connected to the centre of the main pipe and distributive ring is at the end of the nozzle. Its purpose is to evenly distribute cooling water into the superheat steam. Nozzle of the main pipe should not interfere with thermal dilatation. Conical diffuser is in front of the torus in the pipe and it serves for lowering head loss. Diffuser is connected to a shutter which protects the main pipe against cooling water drops.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JP - Průmyslové procesy a zpracování
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
12th International Conference on Developments in Machinery Design and Control
ISBN
978-83-87982-08-9
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
—
Název nakladatele
Kazimierz Peszyński
Místo vydání
Bydgoszcz
Místo konání akce
Nowogród, Polsko
Datum konání akce
9. 9. 2008
Typ akce podle státní příslušnosti
EUR - Evropská akce