The Impact of Thermal Cycles of Superheated Steam on Pipes Material of By-Pass of Steam and Gas-Steam Turbines
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24210%2F15%3A00002615" target="_blank" >RIV/46747885:24210/15:00002615 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/46747885:24620/15:00002615
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Impact of Thermal Cycles of Superheated Steam on Pipes Material of By-Pass of Steam and Gas-Steam Turbines
Popis výsledku v původním jazyce
By-pass station of steam turbines is a device, used to by-pass steam from boiler to condenser by bypassing a turbine. It is especially used while starting operating conditions of a boiler, before putting a turbine-generator unit in service, or in the cases when the amount of stem produced in boiler is higher, then the amount of steam needed for operation of turbine and its accessories. In common operating mode the station is on stand-by and waiting in so called “thermal reserve”. The by-pass station is equipped with reducer, which reduces the pressure to the stated range, and further with cooler reducing steam temperature before entering water-cooled condenser. It can happened (during the breakdown of cooling media supply) that the temperature of flowing steam behind the cooler will rise steeply for a short time and thus the pipes behind the cooler will by thermally loaded. The aim of the submission is to show, if and possibly how the impact of these thermal cycles influences material properties of output pipe of the by-pass station made of creep resistance C-Mn steel P235GH.
Název v anglickém jazyce
The Impact of Thermal Cycles of Superheated Steam on Pipes Material of By-Pass of Steam and Gas-Steam Turbines
Popis výsledku anglicky
By-pass station of steam turbines is a device, used to by-pass steam from boiler to condenser by bypassing a turbine. It is especially used while starting operating conditions of a boiler, before putting a turbine-generator unit in service, or in the cases when the amount of stem produced in boiler is higher, then the amount of steam needed for operation of turbine and its accessories. In common operating mode the station is on stand-by and waiting in so called “thermal reserve”. The by-pass station is equipped with reducer, which reduces the pressure to the stated range, and further with cooler reducing steam temperature before entering water-cooled condenser. It can happened (during the breakdown of cooling media supply) that the temperature of flowing steam behind the cooler will rise steeply for a short time and thus the pipes behind the cooler will by thermally loaded. The aim of the submission is to show, if and possibly how the impact of these thermal cycles influences material properties of output pipe of the by-pass station made of creep resistance C-Mn steel P235GH.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20501 - Materials engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1201" target="_blank" >LO1201: ROZVOJ ÚSTAVU PRO NANOMATERIÁLY, POKROČILÉ TECHNOLOGIE A INOVACE TECHNICKÉ UNIVERZITY V LIBERCI</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
METAL 2015 Conference Proceedings
ISBN
978-80-87294-62-8
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
603-608
Název nakladatele
Tanger Ltd.
Místo vydání
Ostrava
Místo konání akce
Brno
Datum konání akce
1. 1. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—