Strain-Stress Analysis of Lower Limb with Applied Fixator
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F09%3APU83286" target="_blank" >RIV/00216305:26210/09:PU83286 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Strain-Stress Analysis of Lower Limb with Applied Fixator
Popis výsledku v původním jazyce
Treatment of complicated fractures is much more difficult than the treatment of simple fractures. Bone tissue but also soft tissue injuries happen in most cases. That is why plaster bandage cannot be used for fracture fixation. Fixators are used to fixate the fractured bones in this case. Fixators are furthermore used in the treatment of limb imperfections where damaged area must be overbridged. The fixation has principal influence on quality of bone concretion. Fixator must be able to transport the load arising during walking. Stiffness of a system fixator: bone should be the same as stiffness of single bone. The second criteria of fixator functionality is no overloading of bone tissue during the treatment. Two types of the most often applied fixatorswere studied in terms of suggestion from Trauma Hospital of Brno. Both fixators belong to the category of axial fixators. This paper is concerned with the study of stiffness of two systems fixator: bone via strain-stress analysis and the
Název v anglickém jazyce
Strain-Stress Analysis of Lower Limb with Applied Fixator
Popis výsledku anglicky
Treatment of complicated fractures is much more difficult than the treatment of simple fractures. Bone tissue but also soft tissue injuries happen in most cases. That is why plaster bandage cannot be used for fracture fixation. Fixators are used to fixate the fractured bones in this case. Fixators are furthermore used in the treatment of limb imperfections where damaged area must be overbridged. The fixation has principal influence on quality of bone concretion. Fixator must be able to transport the load arising during walking. Stiffness of a system fixator: bone should be the same as stiffness of single bone. The second criteria of fixator functionality is no overloading of bone tissue during the treatment. Two types of the most often applied fixatorswere studied in terms of suggestion from Trauma Hospital of Brno. Both fixators belong to the category of axial fixators. This paper is concerned with the study of stiffness of two systems fixator: bone via strain-stress analysis and the
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JR - Ostatní strojírenství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/2E08017" target="_blank" >2E08017: Postupy a metody pro zvýšení počtu pracovníků ve vědě a výzkumu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
25th Conference with International Participation - Computational Mechanics 2009 - Book of Extended Abstracts
ISBN
978-80-7043-824-4
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
—
Název nakladatele
University of West Bohemia
Místo vydání
Pilsen
Místo konání akce
Hrad Nečtiny
Datum konání akce
9. 11. 2009
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—