Cooling intensity of working rolls is very important in industrial applications. Durability of these rolls strongly depends on proper cooling. In case of working rolls, not covered with a significant water layer, cooling is more effective with full conenozzles than with flat jet nozzles. This paper is focused on the measurements of the cooling intensity for three different types of nozzles performed on an experimental roll which enables to measure thermal boundary conditions which occur on a real working roll. Two flat jet nozzles with different spray angles and same flow rate and one full cone nozzle with half flow rate for equal pressure were tested. The measurements showed that it is possible to achieve the same cooling intensities with half amountof water.
Název v anglickém jazyce
Chladící účinky na pracovní válec ploché trysky versus kuželové trysky
Popis výsledku anglicky
Cooling intensity of working rolls is very important in industrial applications. Durability of these rolls strongly depends on proper cooling. In case of working rolls, not covered with a significant water layer, cooling is more effective with full conenozzles than with flat jet nozzles. This paper is focused on the measurements of the cooling intensity for three different types of nozzles performed on an experimental roll which enables to measure thermal boundary conditions which occur on a real working roll. Two flat jet nozzles with different spray angles and same flow rate and one full cone nozzle with half flow rate for equal pressure were tested. The measurements showed that it is possible to achieve the same cooling intensities with half amountof water.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JG - Hutnictví, kovové materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Engineering Mechanics 2010 - sborník
ISBN
978-80-87012-26-0
ISSN
—
e-ISSN
—
Počet stran výsledku
11
Strana od-do
—
Název nakladatele
Neuveden
Místo vydání
Neuveden
Místo konání akce
Svratka
Datum konání akce
10. 5. 2010
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—