Comparison of Acoustic Emission Signal and X-ray Diffraction at Initial Stages of Fatigue Damage
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F10%3APU88776" target="_blank" >RIV/00216305:26210/10:PU88776 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of Acoustic Emission Signal and X-ray Diffraction at Initial Stages of Fatigue Damage
Popis výsledku v původním jazyce
The contribution treats the evaluation of degradation processes appearing during the cyclic loading of the samples from Al alloys EN AW-2017/T4 and EN AW-6082/T6. Two NDT methods have been applied in this case, namely the acoustic emission (AE) and the X-ray diffraction used to detect the microstructural changes in the material during the fatigue damages as well as to report the microcracks appearing afterwards. These measurements have been completed with reports of changes to the loading (resonance) frequency coming from fatigue loading equipment. Moreover, the article describes the records of AE signal coming from an AE analyser with full scan of signal as it has been newly developed. The main advantage of this type analyser (compared with AE measuring systems currently used) is continuous sampling and full (uninterrupted) signal saving data.
Název v anglickém jazyce
Comparison of Acoustic Emission Signal and X-ray Diffraction at Initial Stages of Fatigue Damage
Popis výsledku anglicky
The contribution treats the evaluation of degradation processes appearing during the cyclic loading of the samples from Al alloys EN AW-2017/T4 and EN AW-6082/T6. Two NDT methods have been applied in this case, namely the acoustic emission (AE) and the X-ray diffraction used to detect the microstructural changes in the material during the fatigue damages as well as to report the microcracks appearing afterwards. These measurements have been completed with reports of changes to the loading (resonance) frequency coming from fatigue loading equipment. Moreover, the article describes the records of AE signal coming from an AE analyser with full scan of signal as it has been newly developed. The main advantage of this type analyser (compared with AE measuring systems currently used) is continuous sampling and full (uninterrupted) signal saving data.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JL - Únava materiálu a lomová mechanika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/1M0556" target="_blank" >1M0556: Ekocentrum aplikovaného výzkumu neželezných kovů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
29th European Conference on AE Testing
ISBN
978-3-200-01956-0
ISSN
—
e-ISSN
—
Počet stran výsledku
9
Strana od-do
—
Název nakladatele
TUV Austria
Místo vydání
Videň
Místo konání akce
Wien
Datum konání akce
8. 9. 2010
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—