Coherence Controlled Holographic Microscopy (CCHM) is a novel holographic technique for quantitative-phase contrast (QPC) biological observations particularly of living cells. Owing to the ordinary (low coherence) illumination source, the CCHM images areof low noise, deprived of coherence noise (speckles) and the lateral resolution is improved by a factor of 2 compared to classic holographic microscopes. Long-lasting time-lapse experiments require elimination of the CCHM optical system instability in order to achieve precise QPC measurement and to maintain correct CCHM adjustment for its low-coherence operation. The critical part of CCHM is the interferometer, which is very sensitive to temperature fluctuations and air turbulences. The temperature stabilization of the whole microscope without air turbulences is therefore required to provide stability for long-term observations of living cells. Novel heated microscope box and stage designed and constructed for this purpose are describe
Název v anglickém jazyce
System for coherence-controlled holographic microscopy of living cells
Popis výsledku anglicky
Coherence Controlled Holographic Microscopy (CCHM) is a novel holographic technique for quantitative-phase contrast (QPC) biological observations particularly of living cells. Owing to the ordinary (low coherence) illumination source, the CCHM images areof low noise, deprived of coherence noise (speckles) and the lateral resolution is improved by a factor of 2 compared to classic holographic microscopes. Long-lasting time-lapse experiments require elimination of the CCHM optical system instability in order to achieve precise QPC measurement and to maintain correct CCHM adjustment for its low-coherence operation. The critical part of CCHM is the interferometer, which is very sensitive to temperature fluctuations and air turbulences. The temperature stabilization of the whole microscope without air turbulences is therefore required to provide stability for long-term observations of living cells. Novel heated microscope box and stage designed and constructed for this purpose are describe
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of SPIE
ISBN
978-80-244-3408-7
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
"869712-1"-"869712-6"
Název nakladatele
SPIE
Místo vydání
Neuveden
Místo konání akce
Ostravice
Datum konání akce
3. 9. 2012
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—