HVAC automotive vents evaluation and their performance
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F13%3APU106788" target="_blank" >RIV/00216305:26210/13:PU106788 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
HVAC automotive vents evaluation and their performance
Popis výsledku v původním jazyce
Car passengers comfort is increasingly important, not only from good feelings or travel comfort point of view, but also from the transportation safety perspective, where the driver s thermal comfort is of crucial importance. The main components affecting optimal comfort are HVAC vents. This article focuses on the performance assessment of a side dashboard car vent with adjustable horizontal vanes that allow changing the air jet direction vertically along with a complete shut-off. A new measuring methodology is presented here; it simulates real and complete ventilation system conditions using a simple laboratory piece of equipment with a single vent mounted. The flow pattern as generated by the vent jet was first studied with smoke visualization, then using a two-wire constant-temperature anemometer probe. Jet orientations and boundaries were identified for particular vent settings, which are fundamental in the assessment of vent performance. The average air speed and turbulence intensity were determined. Results show that the actual jet direction differs substantially from the direction that was set by the vanes and that further research may lead to a new and improved design of automatic control of a zonal ventilation system and contribute to more accurate control of passengers comfort.
Název v anglickém jazyce
HVAC automotive vents evaluation and their performance
Popis výsledku anglicky
Car passengers comfort is increasingly important, not only from good feelings or travel comfort point of view, but also from the transportation safety perspective, where the driver s thermal comfort is of crucial importance. The main components affecting optimal comfort are HVAC vents. This article focuses on the performance assessment of a side dashboard car vent with adjustable horizontal vanes that allow changing the air jet direction vertically along with a complete shut-off. A new measuring methodology is presented here; it simulates real and complete ventilation system conditions using a simple laboratory piece of equipment with a single vent mounted. The flow pattern as generated by the vent jet was first studied with smoke visualization, then using a two-wire constant-temperature anemometer probe. Jet orientations and boundaries were identified for particular vent settings, which are fundamental in the assessment of vent performance. The average air speed and turbulence intensity were determined. Results show that the actual jet direction differs substantially from the direction that was set by the vanes and that further research may lead to a new and improved design of automatic control of a zonal ventilation system and contribute to more accurate control of passengers comfort.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
HVAC&R RESEARCH
ISSN
1078-9669
e-ISSN
—
Svazek periodika
19
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10
Strana od-do
1073-1082
Kód UT WoS článku
000327477000014
EID výsledku v databázi Scopus
—