Experimental analysis of spatial evolution of mean droplet diameters in effervescent sprays
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F14%3APU110816" target="_blank" >RIV/00216305:26210/14:PU110816 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.aidic.it/cet/14/39/131.pdf" target="_blank" >http://www.aidic.it/cet/14/39/131.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3303/CET1439131" target="_blank" >10.3303/CET1439131</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Experimental analysis of spatial evolution of mean droplet diameters in effervescent sprays
Popis výsledku v původním jazyce
Effervescent atomization has established itself in the past decade as a promising alternative to conventional spray formation mechanisms. A great effort is currently being put into understanding the involved phenomena and developing numerical models to predict outcomes of processes relying on effervescent atomizers (i.e. spray combustion, coating, drying). This still proves to be a formidable challenge as effervescent atomization is a complex process involving two phase flow. The presented paper focuses on mean droplet sizes and how they vary throughout effervescent sprays at different operating conditions. The experiment was performed using Phase Doppler Anemometry (PDA) and the droplet data were collected in multiple locations varying both axially and radially. At each measurement location the Sauter Mean Diameter (SMD) was computed. The preliminary results show that closer to the spray nozzle the bigger droplets are concentrated in the spray core, while the small droplets are in the peripheral regions. However, this trend is slowly reversing with increasing distance from the spray nozzle. Finally, from a certain distance the initial trend is completely reversed with the small droplets being in the spray core, while larger droplets are found closer to the edge of the spray. Moreover, this phenomenon seems to be independent of operating conditions. Reasons for such behaviour are suggested and discussed. Furthermore, SMD sensitivity to operating conditions is analysed.
Název v anglickém jazyce
Experimental analysis of spatial evolution of mean droplet diameters in effervescent sprays
Popis výsledku anglicky
Effervescent atomization has established itself in the past decade as a promising alternative to conventional spray formation mechanisms. A great effort is currently being put into understanding the involved phenomena and developing numerical models to predict outcomes of processes relying on effervescent atomizers (i.e. spray combustion, coating, drying). This still proves to be a formidable challenge as effervescent atomization is a complex process involving two phase flow. The presented paper focuses on mean droplet sizes and how they vary throughout effervescent sprays at different operating conditions. The experiment was performed using Phase Doppler Anemometry (PDA) and the droplet data were collected in multiple locations varying both axially and radially. At each measurement location the Sauter Mean Diameter (SMD) was computed. The preliminary results show that closer to the spray nozzle the bigger droplets are concentrated in the spray core, while the small droplets are in the peripheral regions. However, this trend is slowly reversing with increasing distance from the spray nozzle. Finally, from a certain distance the initial trend is completely reversed with the small droplets being in the spray core, while larger droplets are found closer to the edge of the spray. Moreover, this phenomenon seems to be independent of operating conditions. Reasons for such behaviour are suggested and discussed. Furthermore, SMD sensitivity to operating conditions is analysed.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20402 - Chemical process engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1202" target="_blank" >LO1202: NETME CENTRE PLUS</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
17th Conference on Process Integration, Modelling and Optimisation for Energy Saving and Pollution Reduction
ISBN
978-88-95608-30-3
ISSN
2283-9216
e-ISSN
—
Počet stran výsledku
6
Strana od-do
780-786
Název nakladatele
AIDIC Servizi S.r.l.
Místo vydání
Milano
Místo konání akce
Prague
Datum konání akce
23. 8. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000346757600131