Progress of the IR measurement in the area of the fine particulate material water content
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F14%3APU112142" target="_blank" >RIV/00216305:26210/14:PU112142 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Progress of the IR measurement in the area of the fine particulate material water content
Popis výsledku v původním jazyce
The paper compares the results of the test of continuous moisture content measurements of lime hydrate under operating unit production conditions where the infra-red spectroscopy method and the classical method of the mass-decrease of samples in drying chamber were employed. The large differences which two measurement systems show are explained in connection of the changes of the measurement process conditions. The paper shows the taken data of infrared spectral measurement of the powder material moisture content as the function of: the time of the spectral data that are taken; the influence of the false IR radiation; the influence of smoothness of the measured powder material surface; the distance of the measured material surface of the spectral measurement device focus
Název v anglickém jazyce
Progress of the IR measurement in the area of the fine particulate material water content
Popis výsledku anglicky
The paper compares the results of the test of continuous moisture content measurements of lime hydrate under operating unit production conditions where the infra-red spectroscopy method and the classical method of the mass-decrease of samples in drying chamber were employed. The large differences which two measurement systems show are explained in connection of the changes of the measurement process conditions. The paper shows the taken data of infrared spectral measurement of the powder material moisture content as the function of: the time of the spectral data that are taken; the influence of the false IR radiation; the influence of smoothness of the measured powder material surface; the distance of the measured material surface of the spectral measurement device focus
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CI - Průmyslová chemie a chemické inženýrství
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 2nd International Conference on Advances in Applied Science and Environmental Engineering
ISBN
978-1-63248-033-0
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
20-23
Název nakladatele
Institute of Research Engineers and Doctors,
Místo vydání
USA
Místo konání akce
Kuala Lumpur
Datum konání akce
20. 12. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—