Evaluation of human error of response to auditory and visual signals in the virtual reality
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F15%3APU116113" target="_blank" >RIV/00216305:26210/15:PU116113 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation of human error of response to auditory and visual signals in the virtual reality
Popis výsledku v původním jazyce
A design of control panels and desks with regard to operator’s reliability has therefore become a key aspect of technology design. Due to high costs of full-scale experiments of human reliability, virtual reality systems have recently started to be exploited. This paper deals with the experimental evaluation of reliability of staff (operation error rate) operating the panel in the control room in the virtual reality system when testing the control panel design. Factors evaluated are the arrangement of buttons on the panel (horizontal/vertical) and the type of stimulus (visual, auditory). The experiment proved that during the experiment in virtual reality the Operation error rate changes in dependence on the change of control panel arrangement; the influence of stimuli has not been proved.
Název v anglickém jazyce
Evaluation of human error of response to auditory and visual signals in the virtual reality
Popis výsledku anglicky
A design of control panels and desks with regard to operator’s reliability has therefore become a key aspect of technology design. Due to high costs of full-scale experiments of human reliability, virtual reality systems have recently started to be exploited. This paper deals with the experimental evaluation of reliability of staff (operation error rate) operating the panel in the control room in the virtual reality system when testing the control panel design. Factors evaluated are the arrangement of buttons on the panel (horizontal/vertical) and the type of stimulus (visual, auditory). The experiment proved that during the experiment in virtual reality the Operation error rate changes in dependence on the change of control panel arrangement; the influence of stimuli has not been proved.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
30305 - Occupational health
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1202" target="_blank" >LO1202: NETME CENTRE PLUS</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Safety and Reliability of Complex Engineered Systems
ISBN
978-1-138-02879-1
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
2997-3001
Název nakladatele
CRC Press
Místo vydání
London
Místo konání akce
Zürich
Datum konání akce
3. 9. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—