Popis výsledku v původním jazyce
The standard methods of transferring graphene onto semiconductor substrates apply acetone to solve the layer of polymethyl methacrylate (PMMA) on the surface of graphene layer at the end of ‘wet transfer process’. During this process, however, impurities on the order of nanometres get entrapped and have a subsequent negative effect on the practical utilization of graphene in the field of optoelectronics. To optimize the wet transfer of graphene using PMMA as a supporting polymer, several solvents were compared in terms of resulting contamination. The solvents subjected to the research included: acetone, chloroform, dimethyl succinate (DMG), and n-ethyl pyrrolidone (NEP). The lowest graphene contamination at the end of transfer process was achieved with NEP solvent, which was studied using atomic force microscopy (AFM).
Název v anglickém jazyce
STUDY OF THE INFLUENCE OF SOLVENT ON TRANSMISSION QUALITY GRAPHENE
Popis výsledku anglicky
The standard methods of transferring graphene onto semiconductor substrates apply acetone to solve the layer of polymethyl methacrylate (PMMA) on the surface of graphene layer at the end of ‘wet transfer process’. During this process, however, impurities on the order of nanometres get entrapped and have a subsequent negative effect on the practical utilization of graphene in the field of optoelectronics. To optimize the wet transfer of graphene using PMMA as a supporting polymer, several solvents were compared in terms of resulting contamination. The solvents subjected to the research included: acetone, chloroform, dimethyl succinate (DMG), and n-ethyl pyrrolidone (NEP). The lowest graphene contamination at the end of transfer process was achieved with NEP solvent, which was studied using atomic force microscopy (AFM).
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10302 - Condensed matter physics (including formerly solid state physics, supercond.)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
NANOCON 2016
ISBN
978-80-87294-71-0
ISSN
—
e-ISSN
—
Počet stran výsledku
148
Strana od-do
42-42
Název nakladatele
Neuveden
Místo vydání
neuveden
Místo konání akce
Brno
Datum konání akce
19. 10. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000410656100008