Leakage cause analysis of a flange joint designed according to standards
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F17%3APU125109" target="_blank" >RIV/00216305:26210/17:PU125109 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Leakage cause analysis of a flange joint designed according to standards
Popis výsledku v původním jazyce
The design of flanges is linked to the use of relevant standards; in the chemical, petrochemical and energy industries. The modern standards EN 13445 [1], which are focused on design of unfired pressure vessels, are often used to design flanges. There is a danger of possible flange joints leakages in operation. Whether the flange connection is designed with standardized parts where the calculation is not necessary or it is designed by strength calculation according to this standard, such procedure does not ensure that the flange joint is sealed, as will be shown in the article. This situation is, for example, a leak due to insufficient contact pressure on the sealing surfaces. The flange joint undergoes several load-bearing operations. When assembling, the cold flange connection is tightened to the specified pretension. When operating media is introduced, there may be significant changes in stress distribution due to thermal expansion, presenting a transient state between assembly and nominal operatio
Název v anglickém jazyce
Leakage cause analysis of a flange joint designed according to standards
Popis výsledku anglicky
The design of flanges is linked to the use of relevant standards; in the chemical, petrochemical and energy industries. The modern standards EN 13445 [1], which are focused on design of unfired pressure vessels, are often used to design flanges. There is a danger of possible flange joints leakages in operation. Whether the flange connection is designed with standardized parts where the calculation is not necessary or it is designed by strength calculation according to this standard, such procedure does not ensure that the flange joint is sealed, as will be shown in the article. This situation is, for example, a leak due to insufficient contact pressure on the sealing surfaces. The flange joint undergoes several load-bearing operations. When assembling, the cold flange connection is tightened to the specified pretension. When operating media is introduced, there may be significant changes in stress distribution due to thermal expansion, presenting a transient state between assembly and nominal operatio
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
20704 - Energy and fuels
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1202" target="_blank" >LO1202: NETME CENTRE PLUS</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů