SELECTED CHARACTERISTICS AND DIAGNOSTICS OF MOTOR POWERED BY FREQUENCY CONVERTER
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F17%3APU125967" target="_blank" >RIV/00216305:26210/17:PU125967 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.mmscience.eu/content/file/archives/MM_Science_201790.pdf" target="_blank" >http://www.mmscience.eu/content/file/archives/MM_Science_201790.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.17973/MMSJ.2017_12_201790" target="_blank" >10.17973/MMSJ.2017_12_201790</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
SELECTED CHARACTERISTICS AND DIAGNOSTICS OF MOTOR POWERED BY FREQUENCY CONVERTER
Popis výsledku v původním jazyce
All of the technical devices that are powered by the frequency converter, apart from their great advantages, also bring considerable pitfalls and risks. When designing a machinery, it is necessary to consider the negative effects of characteristics of the frequency converter on the rotating parts, especially on the bearings of motors, gearboxes, gears, seals, etc. These devices and their parts are usually exposed to the effects of capacitive and shaft currents that have a considerable impact on the reliability of machines and equipment. This article focuses on the reasons for the use of insulated bearing (or insulated coupling) for asynchronous motors and on the influence of the measures taken to eliminate the adverse effects on the rotating parts. The following is an example of the use of technical diagnostics to determine the condition of some parts of the machinery, the example is evaluated, conclusions are drawn and analysed.
Název v anglickém jazyce
SELECTED CHARACTERISTICS AND DIAGNOSTICS OF MOTOR POWERED BY FREQUENCY CONVERTER
Popis výsledku anglicky
All of the technical devices that are powered by the frequency converter, apart from their great advantages, also bring considerable pitfalls and risks. When designing a machinery, it is necessary to consider the negative effects of characteristics of the frequency converter on the rotating parts, especially on the bearings of motors, gearboxes, gears, seals, etc. These devices and their parts are usually exposed to the effects of capacitive and shaft currents that have a considerable impact on the reliability of machines and equipment. This article focuses on the reasons for the use of insulated bearing (or insulated coupling) for asynchronous motors and on the influence of the measures taken to eliminate the adverse effects on the rotating parts. The following is an example of the use of technical diagnostics to determine the condition of some parts of the machinery, the example is evaluated, conclusions are drawn and analysed.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20306 - Audio engineering, reliability analysis
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
MM Science Journal
ISSN
1803-1269
e-ISSN
1805-0476
Svazek periodika
neuveden
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
7
Strana od-do
2077-2084
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85038076811