Fast Shape-From-Focus method for 3D object reconstruction
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F18%3APU127941" target="_blank" >RIV/00216305:26210/18:PU127941 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0030402618306557?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0030402618306557?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ijleo.2018.05.014" target="_blank" >10.1016/j.ijleo.2018.05.014</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Fast Shape-From-Focus method for 3D object reconstruction
Popis výsledku v původním jazyce
Shape-From-Focus method (SFF method) is a method for recovering depth from an image series which are taken with different focus settings. For method presented in this paper, the series must be taken with an optical device (optical microscope, CCD or classic camera) with very small depth of focus, different images must be focussed to different planes and may be taken with inconsiderable angle of view. Proposed method is capable to registered images with different scaling, it makes possible to construct full sharpened 2D image and also the 3D model of scanned object. Accuracy of the method is tested by comparing with 3D models obtained by confocal microscope in hardware supported confocal mode.
Název v anglickém jazyce
Fast Shape-From-Focus method for 3D object reconstruction
Popis výsledku anglicky
Shape-From-Focus method (SFF method) is a method for recovering depth from an image series which are taken with different focus settings. For method presented in this paper, the series must be taken with an optical device (optical microscope, CCD or classic camera) with very small depth of focus, different images must be focussed to different planes and may be taken with inconsiderable angle of view. Proposed method is capable to registered images with different scaling, it makes possible to construct full sharpened 2D image and also the 3D model of scanned object. Accuracy of the method is tested by comparing with 3D models obtained by confocal microscope in hardware supported confocal mode.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10201 - Computer sciences, information science, bioinformathics (hardware development to be 2.2, social aspect to be 5.8)
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1202" target="_blank" >LO1202: NETME CENTRE PLUS</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
OPTIK
ISSN
0030-4026
e-ISSN
—
Svazek periodika
2018
Číslo periodika v rámci svazku
169
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
11
Strana od-do
16-26
Kód UT WoS článku
000441483900004
EID výsledku v databázi Scopus
2-s2.0-85047249353