Transient Thermal Stress Calculation of a Shell and Tube Condenser with Fixed Tubesheet
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F21%3APU141310" target="_blank" >RIV/00216305:26210/21:PU141310 - isvavai.cz</a>
Výsledek na webu
<a href="https://onlinelibrary.wiley.com/doi/10.1002/cite.202100036" target="_blank" >https://onlinelibrary.wiley.com/doi/10.1002/cite.202100036</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/cite.202100036" target="_blank" >10.1002/cite.202100036</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Transient Thermal Stress Calculation of a Shell and Tube Condenser with Fixed Tubesheet
Popis výsledku v původním jazyce
The present article deals with transient thermal stress calculation on a safety horizontal shell and tube condenser. This condenser is used in a power plant for cooling of hot steam diverted from the turbine in the case of its emergency shutdown. The standard stress calculation was provided according to the EN 13445 standard in steady regime. As consistent with this calculation, an expansion joint must be used on the shell. The main aim of this article is to describe a detailed calculation of the transient temperature field on the shell and tubes, using finite element method analysis, and longitudinal thermal stresses on the shell and tubes during the start-up process. Transient analyses are useable for more accurate EN 13445 calculation and, furthermore, for fatigue calculation.
Název v anglickém jazyce
Transient Thermal Stress Calculation of a Shell and Tube Condenser with Fixed Tubesheet
Popis výsledku anglicky
The present article deals with transient thermal stress calculation on a safety horizontal shell and tube condenser. This condenser is used in a power plant for cooling of hot steam diverted from the turbine in the case of its emergency shutdown. The standard stress calculation was provided according to the EN 13445 standard in steady regime. As consistent with this calculation, an expansion joint must be used on the shell. The main aim of this article is to describe a detailed calculation of the transient temperature field on the shell and tubes, using finite element method analysis, and longitudinal thermal stresses on the shell and tubes during the start-up process. Transient analyses are useable for more accurate EN 13445 calculation and, furthermore, for fatigue calculation.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20402 - Chemical process engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/EF16_026%2F0008413" target="_blank" >EF16_026/0008413: Strategické partnerství pro environmentální technologie a produkci energie</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
CHEMIE INGENIEUR TECHNIK
ISSN
0009-286X
e-ISSN
1522-2640
Svazek periodika
93
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
8
Strana od-do
1590-1597
Kód UT WoS článku
000680525100001
EID výsledku v databázi Scopus
2-s2.0-85112028770