Raman analysis of chemisorbed tribofilm for metal-on-polyethylene hip joint prostheses
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F21%3APU141423" target="_blank" >RIV/00216305:26210/21:PU141423 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14310/21:00124046
Výsledek na webu
<a href="https://ietresearch.onlinelibrary.wiley.com/doi/10.1049/bsb2.12008" target="_blank" >https://ietresearch.onlinelibrary.wiley.com/doi/10.1049/bsb2.12008</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1049/bsb2.12008" target="_blank" >10.1049/bsb2.12008</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Raman analysis of chemisorbed tribofilm for metal-on-polyethylene hip joint prostheses
Popis výsledku v původním jazyce
The biochemical reaction during the formation of lubricant film the in case of a cobalt-chromium ball on an ultrahigh-molecular weight polyethylene cup was studied. Three types of model synovial fluids and hyaluronic acid (HA) at physiologic concentrations were used in the experiment. The coefficient of friction was measured using a pendulum hip simulator, and Raman spectroscopy was used to perceive chemical reactions between the synovial fluid and implant material. Raman spectra evidenced that the three model fluids and HA chemisorbed onto the cobalt-chromium surface. An α-helix structure of the model fluid components was detected on the surface of the prosthesis.
Název v anglickém jazyce
Raman analysis of chemisorbed tribofilm for metal-on-polyethylene hip joint prostheses
Popis výsledku anglicky
The biochemical reaction during the formation of lubricant film the in case of a cobalt-chromium ball on an ultrahigh-molecular weight polyethylene cup was studied. Three types of model synovial fluids and hyaluronic acid (HA) at physiologic concentrations were used in the experiment. The coefficient of friction was measured using a pendulum hip simulator, and Raman spectroscopy was used to perceive chemical reactions between the synovial fluid and implant material. Raman spectra evidenced that the three model fluids and HA chemisorbed onto the cobalt-chromium surface. An α-helix structure of the model fluid components was detected on the surface of the prosthesis.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20301 - Mechanical engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GA20-00483S" target="_blank" >GA20-00483S: Vliv viskosuplementace kloubní kapaliny na tření a mazání</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biosurface and Biotribology
ISSN
2405-4518
e-ISSN
—
Svazek periodika
7
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
11
Strana od-do
1-11
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85106243247