Advances in the Dynamics of Magnetorheological Actuators
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F22%3APU145814" target="_blank" >RIV/00216305:26210/22:PU145814 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=9899187&tag=1" target="_blank" >https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=9899187&tag=1</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Advances in the Dynamics of Magnetorheological Actuators
Popis výsledku v původním jazyce
Short response time of magnetorheological (MR) valve is important parameter influencing performance of the suspension system controlled by some of fast semiactive algorithm. The main sources of MR actuator’s response time were identified as particle microstructure development in MR fluid, driving electronic response time caused by inductance of the coil, eddy currents in the magnetic circuit and MR actuator compliance. The response time of MR actuator can be significantly reduced by couple of approaches. The rise or drop of electric current can be reduced using over-voltage method and by multi coil design. The effect of eddy currents can be limited using material or shape approach. Experimental results showed that the response time up to 1.3 ms can be reached for magnetorheological damper with structured magnetic circuit.
Název v anglickém jazyce
Advances in the Dynamics of Magnetorheological Actuators
Popis výsledku anglicky
Short response time of magnetorheological (MR) valve is important parameter influencing performance of the suspension system controlled by some of fast semiactive algorithm. The main sources of MR actuator’s response time were identified as particle microstructure development in MR fluid, driving electronic response time caused by inductance of the coil, eddy currents in the magnetic circuit and MR actuator compliance. The response time of MR actuator can be significantly reduced by couple of approaches. The rise or drop of electric current can be reduced using over-voltage method and by multi coil design. The effect of eddy currents can be limited using material or shape approach. Experimental results showed that the response time up to 1.3 ms can be reached for magnetorheological damper with structured magnetic circuit.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20501 - Materials engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GJ20-23261Y" target="_blank" >GJ20-23261Y: Studium časové odezvy magnetoreologické kapaliny</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
ACTUATOR 2022; International Conference and Exhibition on New Actuator Systems and Applications
ISBN
978-3-8007-5894-4
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
138-141
Název nakladatele
VDE
Místo vydání
neuveden
Místo konání akce
Mannheim
Datum konání akce
29. 6. 2022
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—