Optimizing the thermal performance of the thermosyphon heat pipe for energy saving with graphene oxide nanofluid
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F23%3APU150567" target="_blank" >RIV/00216305:26210/23:PU150567 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0360544223008162?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0360544223008162?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.energy.2023.127422" target="_blank" >10.1016/j.energy.2023.127422</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Optimizing the thermal performance of the thermosyphon heat pipe for energy saving with graphene oxide nanofluid
Popis výsledku v původním jazyce
A thermosyphon heat pipe (THP) involves a vacuum tube with a specific quantity of liquid. Due to its simplicity of design and structure, THP has many applications in heat recovery and renewable energy devices. Prior studies showed that using stable nanofluids can improve THPs' energy efficiency. In this evaluation, the effect of working fluid type, input heat, two types of surfactants, and nanoparticle concentration on the energy efficiency and thermal resistance of a THP was investigated and optimized. A magnetic stirrer and ultrasonic waves were used to create stability. Imaging and spectrophotometric analysis showed that graphene oxide (GO) nanofluid with SDS surfactant is more stable. The most notable decrease in thermal resistance at an input power of 100 W with GO nanofluids compared to distilled water at an F.R. of 50% was 12%. The highest decrease in the evap-orator temperature section was achieved with GO and SDS surfactant at a weight ratio of 0.3% wt, equal to 12.3 degrees C. This was also confirmed by measuring the contact angle. The highest percentage increase in thermal efficiency of THP with the mixture of GO nanoparticles and SDS surfactant in distilled water with 0.3 wt percent and input heat of 200 W was 18% compared to distilled water. In the optimum condition, the highest percentage increase in thermal efficiency of THP with the mixture of GO nanoparticles and SDS surfactant in distilled water with 0.3 wt percent and input heat of 200 W was 18% compared to distilled water.
Název v anglickém jazyce
Optimizing the thermal performance of the thermosyphon heat pipe for energy saving with graphene oxide nanofluid
Popis výsledku anglicky
A thermosyphon heat pipe (THP) involves a vacuum tube with a specific quantity of liquid. Due to its simplicity of design and structure, THP has many applications in heat recovery and renewable energy devices. Prior studies showed that using stable nanofluids can improve THPs' energy efficiency. In this evaluation, the effect of working fluid type, input heat, two types of surfactants, and nanoparticle concentration on the energy efficiency and thermal resistance of a THP was investigated and optimized. A magnetic stirrer and ultrasonic waves were used to create stability. Imaging and spectrophotometric analysis showed that graphene oxide (GO) nanofluid with SDS surfactant is more stable. The most notable decrease in thermal resistance at an input power of 100 W with GO nanofluids compared to distilled water at an F.R. of 50% was 12%. The highest decrease in the evap-orator temperature section was achieved with GO and SDS surfactant at a weight ratio of 0.3% wt, equal to 12.3 degrees C. This was also confirmed by measuring the contact angle. The highest percentage increase in thermal efficiency of THP with the mixture of GO nanoparticles and SDS surfactant in distilled water with 0.3 wt percent and input heat of 200 W was 18% compared to distilled water. In the optimum condition, the highest percentage increase in thermal efficiency of THP with the mixture of GO nanoparticles and SDS surfactant in distilled water with 0.3 wt percent and input heat of 200 W was 18% compared to distilled water.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20303 - Thermodynamics
Návaznosti výsledku
Projekt
<a href="/cs/project/EF15_003%2F0000456" target="_blank" >EF15_003/0000456: Laboratoř integrace procesů pro trvalou udržitelnost</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Energy
ISSN
0360-5442
e-ISSN
1873-6785
Svazek periodika
neuveden
Číslo periodika v rámci svazku
274
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
10
Strana od-do
„“-„“
Kód UT WoS článku
000982289600001
EID výsledku v databázi Scopus
2-s2.0-85151874218