Popis výsledku v původním jazyce
Fast detection of pesticide toxicity in the field conditions is very important in many aspects (longtime influence of low concentrations on man s health, pesticide storage, price of one test etc.). The pesticide concentration measurements are performed on a biosensor with acetylcholinesterase (AChE). The AChE is a very sensitive compound. The measurement uses principle of an artificial synapse (AS) and inhibition of an enzyme Acetylcholinesterase (AChE). The AS is a very effective detector of the pesticcide toxicity. Therefore properties of the sensor have to be measured without AChE at first. This process is called input control of the sensor. The reproducibility of electrochemical detector is studied first using hydrogen peroxide and second ferri-ferrokyanide redox couple. The parameters of electrochemical detector itself were evaluated statistically.
Název v anglickém jazyce
INPUT CONTROL OF SENSOR PARAMETERS AND REPRODUCIBILITY OF SENSOR MEASUREMENT
Popis výsledku anglicky
Fast detection of pesticide toxicity in the field conditions is very important in many aspects (longtime influence of low concentrations on man s health, pesticide storage, price of one test etc.). The pesticide concentration measurements are performed on a biosensor with acetylcholinesterase (AChE). The AChE is a very sensitive compound. The measurement uses principle of an artificial synapse (AS) and inhibition of an enzyme Acetylcholinesterase (AChE). The AS is a very effective detector of the pesticcide toxicity. Therefore properties of the sensor have to be measured without AChE at first. This process is called input control of the sensor. The reproducibility of electrochemical detector is studied first using hydrogen peroxide and second ferri-ferrokyanide redox couple. The parameters of electrochemical detector itself were evaluated statistically.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
XVII IMEKO WORLD CONGRESS
ISBN
953-7124-00-2
ISSN
—
e-ISSN
—
Počet stran výsledku
3
Strana od-do
2141-2143
Název nakladatele
Neuveden
Místo vydání
Chorvatsko
Místo konání akce
Dubrovnik, Croatia
Datum konání akce
22. 6. 2003
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—