Reproducibility of measurement of organophosphorous pesticides toxicity
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F03%3APU38663" target="_blank" >RIV/00216305:26220/03:PU38663 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Reproducibility of measurement of organophosphorous pesticides toxicity
Popis výsledku v původním jazyce
Fast detection of pesticide toxicity in the field conditions is very important in many aspects (pesticide storage, price of one test etc.). The measurement uses principle of an artificial synapse (AS) and inhibition of an enzyme Acetylcholinesterase (AChE). The AS is a very effective detector of the pesticide detector. This information is very different from classical analytic method data. The enzyme is sensitive to many external influences and its function is significantly influenced by immobilizationprocess. Therefore properties of the sensor have to be measured without AChE at first. This process is called input control of the sensor. The reproducibility of electrochemical detector was studied first using hydrogen peroxide and second ferri-ferrokyanide redox couple. Longterm stability and reproducibility of preparation of enzymatic layer were studied. Cell data was evaluated statistically. This article describes measurement on AS and determination properties of electrochemical sens
Název v anglickém jazyce
Reproducibility of measurement of organophosphorous pesticides toxicity
Popis výsledku anglicky
Fast detection of pesticide toxicity in the field conditions is very important in many aspects (pesticide storage, price of one test etc.). The measurement uses principle of an artificial synapse (AS) and inhibition of an enzyme Acetylcholinesterase (AChE). The AS is a very effective detector of the pesticide detector. This information is very different from classical analytic method data. The enzyme is sensitive to many external influences and its function is significantly influenced by immobilizationprocess. Therefore properties of the sensor have to be measured without AChE at first. This process is called input control of the sensor. The reproducibility of electrochemical detector was studied first using hydrogen peroxide and second ferri-ferrokyanide redox couple. Longterm stability and reproducibility of preparation of enzymatic layer were studied. Cell data was evaluated statistically. This article describes measurement on AS and determination properties of electrochemical sens
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Second IEEE International Conference on Senosrs
ISBN
0-7803-8134-3
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
651-655
Název nakladatele
Neuveden
Místo vydání
Toronto
Místo konání akce
Toronto
Datum konání akce
22. 10. 2003
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—