A Magnetic Resonance Measurement Technique for Rapidly Switched Gradient Magnetic Fields in a Magnetic Resonance Tomograph
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F03%3APU39066" target="_blank" >RIV/00216305:26220/03:PU39066 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68081731:_____/03:12030100
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A Magnetic Resonance Measurement Technique for Rapidly Switched Gradient Magnetic Fields in a Magnetic Resonance Tomograph
Popis výsledku v původním jazyce
The paper describes the method of measurement of the gradient magnetic field in Nuclear Magnetic Resonance (NMR) tomography, which is one of the modern medicine diagnostic methods. The very important prerequisite for imaging of high quality is the gradient magnetic field in the instrument with exactly defined properties. Nuclear magnetic resonance gives to us the possibility to measure the pulse gradient magnetic field characteristics with a high accuracy. The interesting precise methods were designed,realised, and tested in Institute of Scientific Instruments (ISI) of Academy of Sciences of Czech Republic. The first of them was Instantaneous Frequency (IF) method, which had been developed into Instantaneous Frequency of Spin Echo (IFSE) and Instantaneous Frequency of Spin Echo Series (IFSES) methods. The above named methods are described in this paper and their comparison is also presented.
Název v anglickém jazyce
A Magnetic Resonance Measurement Technique for Rapidly Switched Gradient Magnetic Fields in a Magnetic Resonance Tomograph
Popis výsledku anglicky
The paper describes the method of measurement of the gradient magnetic field in Nuclear Magnetic Resonance (NMR) tomography, which is one of the modern medicine diagnostic methods. The very important prerequisite for imaging of high quality is the gradient magnetic field in the instrument with exactly defined properties. Nuclear magnetic resonance gives to us the possibility to measure the pulse gradient magnetic field characteristics with a high accuracy. The interesting precise methods were designed,realised, and tested in Institute of Scientific Instruments (ISI) of Academy of Sciences of Czech Republic. The first of them was Instantaneous Frequency (IF) method, which had been developed into Instantaneous Frequency of Spin Echo (IFSE) and Instantaneous Frequency of Spin Echo Series (IFSES) methods. The above named methods are described in this paper and their comparison is also presented.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/IAA2065201" target="_blank" >IAA2065201: Generace a měření gradientních magnetických polí pro in vivo MR lokalizovanou spektroskopii</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Polytechnica
ISSN
1210-2709
e-ISSN
—
Svazek periodika
2003
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
30-35
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—