Image Data Based Method for 3D Ultrasonic Data Positioning
Popis výsledku v původním jazyce
In the free-hand 3D ultrasonography, the position of the us. probe of a 2D ultrasound scanner is sensed by a special positioning subsystem so that the us. data are accompanied by the positional data. The resulting 3D data should permit flexible visualization and more accurate volume measurements than can be achieved using isolated 2D B-scans; however, the use of the position sensor may be inconvenient for the clinician and, moreover, the main disadvantage is that these position sensors are not accurateeenough and calibration of the measuring equipment may be too complicated. The objective of the presented work is thus to replace the positioning sensor with a technique to estimate the probe trajectory based on the B-scan images themselves. Some publications on such techniques exist, based on speckle correlation analysis. In this paper, we propose a method of a different kind expected to enable accurate positioning using image-data registering based algorithm, including possible modific
Název v anglickém jazyce
Image Data Based Method for 3D Ultrasonic Data Positioning
Popis výsledku anglicky
In the free-hand 3D ultrasonography, the position of the us. probe of a 2D ultrasound scanner is sensed by a special positioning subsystem so that the us. data are accompanied by the positional data. The resulting 3D data should permit flexible visualization and more accurate volume measurements than can be achieved using isolated 2D B-scans; however, the use of the position sensor may be inconvenient for the clinician and, moreover, the main disadvantage is that these position sensors are not accurateeenough and calibration of the measuring equipment may be too complicated. The objective of the presented work is thus to replace the positioning sensor with a technique to estimate the probe trajectory based on the B-scan images themselves. Some publications on such techniques exist, based on speckle correlation analysis. In this paper, we propose a method of a different kind expected to enable accurate positioning using image-data registering based algorithm, including possible modific
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F02%2F0890" target="_blank" >GA102/02/0890: Analýza medicínských ultrasonografických dat se zaměřením na 3D zobrazení v kardiologii</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Analysis of Biomedical Signals and Images - Proceedings of 17th Biennial International EURASIP Conference BIOSIGNAL 2004
ISBN
80-214-2633-0
ISSN
—
e-ISSN
—
Počet stran výsledku
3
Strana od-do
337-339
Název nakladatele
VUTIUM Press
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
23. 6. 2004
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—