Method for Compilation of 3D Ultrasonic Data Based on Image Matching Technique
Popis výsledku v původním jazyce
In free-hand 3D ultrasound, a position sensor is attached to the probe of a 2D ultrasound scanner. The resulting 3D data should permit flexible visualization and more accurate volume measurement than can be achieved using 2D B-scans alone; however the use of the position sensor can be inconvenient for the clinician but the main disadvantage is that these position sensors are not accurate enough and calibration of this is too complicated. The objective is thus to replace the sensor with a technique for eestimating the probe trajectory based on the B-scan images themselves. Some publications on such techniques exist, based on a speckle correlation algorithm. In this paper we propose a method of this kind to accurate positioning using speckle correlationbased algorithm, including possible modification.
Název v anglickém jazyce
Method for Compilation of 3D Ultrasonic Data Based on Image Matching Technique
Popis výsledku anglicky
In free-hand 3D ultrasound, a position sensor is attached to the probe of a 2D ultrasound scanner. The resulting 3D data should permit flexible visualization and more accurate volume measurement than can be achieved using 2D B-scans alone; however the use of the position sensor can be inconvenient for the clinician but the main disadvantage is that these position sensors are not accurate enough and calibration of this is too complicated. The objective is thus to replace the sensor with a technique for eestimating the probe trajectory based on the B-scan images themselves. Some publications on such techniques exist, based on a speckle correlation algorithm. In this paper we propose a method of this kind to accurate positioning using speckle correlationbased algorithm, including possible modification.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F02%2F0890" target="_blank" >GA102/02/0890: Analýza medicínských ultrasonografických dat se zaměřením na 3D zobrazení v kardiologii</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of 10th Conference and Competition the STUDENT EEICT 2004
ISBN
80-214-2635-7
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
183-187
Název nakladatele
FEKT, VUT v Brne
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
29. 6. 2004
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—