Imaging of Ultrasound Attenuation Coefficient
Popis výsledku v původním jazyce
The paper studies imaging of tissue-specific ultrasound attenuation. Ultrasound attenuation parameters are closely related to the type and the pathological state of the tissue. Therefore, the estimated attenuation parameters can be used as a feature in quantitative tissue characterization. Ultrasound attenuation is also an important factor affecting spatial resolution of ultrasound images since the higher ultrasonic frequencies are attenuated more than the lower ones. Knowing the attenuation as a functiion of frequency and depth allows estimation of the depth-dependent point spread function component caused by attenuation. This component can be used to improve the spatial resolution of the ultrasound image through deconvolution. This paper introduces amethod, for tracking the attenuation coefficient in B-mode ultrasonic images on a pixel-by-pixel basis. The resulting parametric images show the mean attenuation coefficient between the probe and a given pixel position, later referred to
Název v anglickém jazyce
Imaging of Ultrasound Attenuation Coefficient
Popis výsledku anglicky
The paper studies imaging of tissue-specific ultrasound attenuation. Ultrasound attenuation parameters are closely related to the type and the pathological state of the tissue. Therefore, the estimated attenuation parameters can be used as a feature in quantitative tissue characterization. Ultrasound attenuation is also an important factor affecting spatial resolution of ultrasound images since the higher ultrasonic frequencies are attenuated more than the lower ones. Knowing the attenuation as a functiion of frequency and depth allows estimation of the depth-dependent point spread function component caused by attenuation. This component can be used to improve the spatial resolution of the ultrasound image through deconvolution. This paper introduces amethod, for tracking the attenuation coefficient in B-mode ultrasonic images on a pixel-by-pixel basis. The resulting parametric images show the mean attenuation coefficient between the probe and a given pixel position, later referred to
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JD - Využití počítačů, robotika a její aplikace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F02%2F0890" target="_blank" >GA102/02/0890: Analýza medicínských ultrasonografických dat se zaměřením na 3D zobrazení v kardiologii</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Technology and Health Care, Int. Journal of Health Care Engineering
ISSN
0928-7329
e-ISSN
—
Svazek periodika
12
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
2
Strana od-do
172-173
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—