Odhad ultrazvukového koeficientu útlumu pomocí zpracování v oblasti log-spektra
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F04%3APU46292" target="_blank" >RIV/00216305:26220/04:PU46292 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Estimation of ultrasound attenuation coefficient using log-spectrum domain processing
Popis výsledku v původním jazyce
Ultrasound attenuation coefficient is an important diagnostic parameter in medical ultrasonography. Furthermore, it is a parameter of a component related to the attenuation process of the space-variant point spread function, which can be used to improvethe spatial resolution of ultrasound images through deconvolution. In this paper, a recently published approach to the estimation of the ultrasound attenuation coefficient from B-scan radiofrequency data is extended and explained in a detail. First, a paarametric image of the mean attenuation coefficients between the probe and a given pixel position is computed by applying linear regression to log-spectra of short segments of radiofrequency signals. Three methods of forming the parametric image are presented. As a second step, the local tissue-specific attenuation coefficients are estimated in small regions of the obtained parametric image. The method has been tested on synthetic radiofrequency data and on radiofrequency data recorded fr
Název v anglickém jazyce
Estimation of ultrasound attenuation coefficient using log-spectrum domain processing
Popis výsledku anglicky
Ultrasound attenuation coefficient is an important diagnostic parameter in medical ultrasonography. Furthermore, it is a parameter of a component related to the attenuation process of the space-variant point spread function, which can be used to improvethe spatial resolution of ultrasound images through deconvolution. In this paper, a recently published approach to the estimation of the ultrasound attenuation coefficient from B-scan radiofrequency data is extended and explained in a detail. First, a paarametric image of the mean attenuation coefficients between the probe and a given pixel position is computed by applying linear regression to log-spectra of short segments of radiofrequency signals. Three methods of forming the parametric image are presented. As a second step, the local tissue-specific attenuation coefficients are estimated in small regions of the obtained parametric image. The method has been tested on synthetic radiofrequency data and on radiofrequency data recorded fr
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JD - Využití počítačů, robotika a její aplikace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F02%2F0890" target="_blank" >GA102/02/0890: Analýza medicínských ultrasonografických dat se zaměřením na 3D zobrazení v kardiologii</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 26th Annual Int. Conf. of the IEEE EMBS
ISBN
0-7803-8440-7
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
1411-1414
Název nakladatele
IEEE inc.
Místo vydání
USA
Místo konání akce
San Francisco
Datum konání akce
1. 9. 2004
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—