Použití EIT TV-PDIPM algoritmu při identifikaci konduktivity elektrod.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F04%3APU46896" target="_blank" >RIV/00216305:26220/04:PU46896 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Idenfitication of Conductivity of Electrodes using EIT Total Variation primal-dual method
Popis výsledku v původním jazyce
In electrical impedance tomography (EIT) currents are applied through the electrodes attached on the surface of the object, and the resulting voltages are measured using the same or additional electrodes. Internal conductivity distribution is recalculated from the measured voltages and currents. The contact conductance between the electrode and the object is a source of deformation field and it has to be taken into account in image reconstruction. As the physical dimensions of the volume conductivity annd the contact conductivity are different, it is difficult to include both quantities in different regularization terms. In the paper we propose a simple modification model of contact conductivity so that it can be used in the total variation regularization term.
Název v anglickém jazyce
Idenfitication of Conductivity of Electrodes using EIT Total Variation primal-dual method
Popis výsledku anglicky
In electrical impedance tomography (EIT) currents are applied through the electrodes attached on the surface of the object, and the resulting voltages are measured using the same or additional electrodes. Internal conductivity distribution is recalculated from the measured voltages and currents. The contact conductance between the electrode and the object is a source of deformation field and it has to be taken into account in image reconstruction. As the physical dimensions of the volume conductivity annd the contact conductivity are different, it is difficult to include both quantities in different regularization terms. In the paper we propose a simple modification model of contact conductivity so that it can be used in the total variation regularization term.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F03%2F1108" target="_blank" >GA102/03/1108: Elektrická impedanční tomografie ve ztrátovém prostředí</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the WSEAS International Conferences
ISBN
960-8457-07-6
ISSN
—
e-ISSN
—
Počet stran výsledku
3
Strana od-do
3013-3015
Název nakladatele
WSEAS
Místo vydání
Athens
Místo konání akce
Atheny
Datum konání akce
28. 12. 2004
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—