Ecg Segment Variability During Voltage Sensitive Dye Application in Animal Heart
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F05%3APU52787" target="_blank" >RIV/00216305:26220/05:PU52787 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/05:00013328
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Ecg Segment Variability During Voltage Sensitive Dye Application in Animal Heart
Popis výsledku v původním jazyce
The optical mapping of action potentials from heart surface is extensively used as a new possibility of non-invasive recording methods. It employs application of voltage-sensitive dyes (VSDs). Previously, VSDs has been successfully used in myocardial ischemia studies. Our previous Langendorff perfused heart experiments that have suggested shape changes in ECG signals in time and time-frequency domain caused by application of VSD di-4-ANEPPS during optical mapping. These changes went through detailed anaalysis to reveal impact to particular fractions of a heart cycle. The heart cycle was divided into three parts, corresponded to P-Q segments, QRS complexes, and ST-T segments. Dynamic time warping (DTW) is applied to all marked segments in each experimental period (control, loading and washout phase). Variability of ECG parts is measured by means of an optimal path resulting from DTW based on minimum distance between the control signal segments (before the application of VSD) and segment
Název v anglickém jazyce
Ecg Segment Variability During Voltage Sensitive Dye Application in Animal Heart
Popis výsledku anglicky
The optical mapping of action potentials from heart surface is extensively used as a new possibility of non-invasive recording methods. It employs application of voltage-sensitive dyes (VSDs). Previously, VSDs has been successfully used in myocardial ischemia studies. Our previous Langendorff perfused heart experiments that have suggested shape changes in ECG signals in time and time-frequency domain caused by application of VSD di-4-ANEPPS during optical mapping. These changes went through detailed anaalysis to reveal impact to particular fractions of a heart cycle. The heart cycle was divided into three parts, corresponded to P-Q segments, QRS complexes, and ST-T segments. Dynamic time warping (DTW) is applied to all marked segments in each experimental period (control, loading and washout phase). Variability of ECG parts is measured by means of an optimal path resulting from DTW based on minimum distance between the control signal segments (before the application of VSD) and segment
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JD - Využití počítačů, robotika a její aplikace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Scripta medica
ISSN
1211-3395
e-ISSN
—
Svazek periodika
78
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
8
Strana od-do
273-280
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—