Měření difuse jader v biologických systémech metodami NMR: kontrola kvality gradientních magnetických polí
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F06%3APU57495" target="_blank" >RIV/00216305:26220/06:PU57495 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68081731:_____/06:00051386
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measuring the Diffusion of Nuclei in Biological Systems by Magnetic Resonance Methods: Checking the Quality of Gradient Magnetic Fields
Popis výsledku v původním jazyce
Imaging techniques based on the principle of nuclear magnetic resonance (MRI) can be used in the study of molecular transport phenomena in biological systems such as self-diffusion processes. The precision of determining the diffusion constants depends on generating the gradient pulse with high precision. For the purpose of determining the characteristics of time behaviour of gradient pulses a simple measuring method was developed and experimentally tested on a 4.7 T tomograph. The method is based on thhe principle of measuring the instantaneous frequency of MR signal in the presence of gradient pulse after the excitation of a thin defined layer of the examined specimen placed outside the gradient field centre. Using the above method, errors were foundin the amplitude and time integral of generated gradient fields and in determining the diffusion constants for biological tissues.
Název v anglickém jazyce
Measuring the Diffusion of Nuclei in Biological Systems by Magnetic Resonance Methods: Checking the Quality of Gradient Magnetic Fields
Popis výsledku anglicky
Imaging techniques based on the principle of nuclear magnetic resonance (MRI) can be used in the study of molecular transport phenomena in biological systems such as self-diffusion processes. The precision of determining the diffusion constants depends on generating the gradient pulse with high precision. For the purpose of determining the characteristics of time behaviour of gradient pulses a simple measuring method was developed and experimentally tested on a 4.7 T tomograph. The method is based on thhe principle of measuring the instantaneous frequency of MR signal in the presence of gradient pulse after the excitation of a thin defined layer of the examined specimen placed outside the gradient field centre. Using the above method, errors were foundin the amplitude and time integral of generated gradient fields and in determining the diffusion constants for biological tissues.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Internetional Conference on Systems
ISBN
0-7695-2552-0
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
1-5
Název nakladatele
IEEE, Computer Society
Místo vydání
Morne
Místo konání akce
Morne
Datum konání akce
26. 4. 2006
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—