Testování kvality gradientního pole pro měření difůze metodamy Magnetické resonance
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F06%3APU63687" target="_blank" >RIV/00216305:26220/06:PU63687 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Testing the quality of magnetic gradient fields for studying self-diffusion processes in biological specimens by magnetic resonance methods
Popis výsledku v původním jazyce
Imaging techniques based on the principle of nuclear magnetic resonance (MRI) can be used in the study of molecular transport phenomena in biological systems such as self-diffusion processes. The precision of determining the diffusion constants depends on generating the gradient pulse with high precision. For the purpose of determining the characteristics of time behaviour of gradient pulses a simple measuring method was developed and experimentally tested on a 4.7 T tomograph. The method is based on the principle of measuring the instantaneous frequency of MR signal in the presence of gradient pulse after the excitation of a thin defined layer of the examined specimen placed outside the gradient field centre. Using the above method, errors were foundin the amplitude and time integral of generated gradient fields and in determining the diffusion constants for biological tissues.
Název v anglickém jazyce
Testing the quality of magnetic gradient fields for studying self-diffusion processes in biological specimens by magnetic resonance methods
Popis výsledku anglicky
Imaging techniques based on the principle of nuclear magnetic resonance (MRI) can be used in the study of molecular transport phenomena in biological systems such as self-diffusion processes. The precision of determining the diffusion constants depends on generating the gradient pulse with high precision. For the purpose of determining the characteristics of time behaviour of gradient pulses a simple measuring method was developed and experimentally tested on a 4.7 T tomograph. The method is based on the principle of measuring the instantaneous frequency of MR signal in the presence of gradient pulse after the excitation of a thin defined layer of the examined specimen placed outside the gradient field centre. Using the above method, errors were foundin the amplitude and time integral of generated gradient fields and in determining the diffusion constants for biological tissues.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/KJB208130603" target="_blank" >KJB208130603: Měření a simulace vlivu susceptibility a vodivosti v MR tomografii</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
APCCAS06 proceeding
ISBN
1-4244-0387-1
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
1-4
Název nakladatele
IEEE
Místo vydání
Singapore
Místo konání akce
Singapore
Datum konání akce
4. 12. 2006
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—