VHDL-AMS MODELING OF DC-DC CONVERTERS FOR STEADYSTATE ANALYSIS
Popis výsledku v původním jazyce
The paper describes a technique for creating behavioral models of switched DC-DC converters based on a combination of the averaged and the switch-level modeling styles, which allows performing steady-state analysis using a single run of the standard Spice transient simulation. The averaging consists in creating an equivalent model of DC-DC converter for quantities averaged over the switching period. Finding the DC operating point of an averaged model is equivalent to finding the steady-state solution inthe switch-level model. Standard transient simulation with the DC operating point as the initial condition is then equivalent to the steady-state analysis. The technique of modified PWM switch is used, which allows incorporating the on-resistance of theactive switch together with the forward voltage drop and the differential resistance of diode-type passive switch. This approach allows sharing the values of state variables between DC and transient analyses.
Název v anglickém jazyce
VHDL-AMS MODELING OF DC-DC CONVERTERS FOR STEADYSTATE ANALYSIS
Popis výsledku anglicky
The paper describes a technique for creating behavioral models of switched DC-DC converters based on a combination of the averaged and the switch-level modeling styles, which allows performing steady-state analysis using a single run of the standard Spice transient simulation. The averaging consists in creating an equivalent model of DC-DC converter for quantities averaged over the switching period. Finding the DC operating point of an averaged model is equivalent to finding the steady-state solution inthe switch-level model. Standard transient simulation with the DC operating point as the initial condition is then equivalent to the steady-state analysis. The technique of modified PWM switch is used, which allows incorporating the on-resistance of theactive switch together with the forward voltage drop and the differential resistance of diode-type passive switch. This approach allows sharing the values of state variables between DC and transient analyses.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F08%2F0784" target="_blank" >GA102/08/0784: Speciální metody modelování a simulace spínaných obvodů</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proc. of the 15th International Conference MIXED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS
ISBN
83-922632-7-8
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
Technical University of Lodz
Místo vydání
Poland
Místo konání akce
Poznaň
Datum konání akce
19. 6. 2008
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—