Elektronické monitorování polohy hlavy po vitrektomii
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F08%3APU77567" target="_blank" >RIV/00216305:26220/08:PU77567 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electronic monitoring of head position after vitrectomy
Popis výsledku v původním jazyce
A developing electronic monitoring system is intended to help patients with maintaining an optimum head position during the recovery process after an ophthalmologic surgery procedure called vitrectomy. In the final phase of this operation a bubble of expansive gas (SF6 or C3F8) is injected into the eye to push recovering parts of the retina together. Positioning the head correctly for a period of several days or even weeks is then crucial for achieving optimal treatment results. The designed head-mounted intelligent device continuously monitors the head position and immediately warns the patient whenever detected position is out of the desired boundaries set by the clinician. The position of the head is described by the angle of tilt in all axes. As asensing element a 3D MEMS accelerometer is utilized. Digital signal processing is used for noise suppression, tilt angle calculation and for calibrating the sensor. Position data is stored into a built-in flash memory in regular intervals
Název v anglickém jazyce
Electronic monitoring of head position after vitrectomy
Popis výsledku anglicky
A developing electronic monitoring system is intended to help patients with maintaining an optimum head position during the recovery process after an ophthalmologic surgery procedure called vitrectomy. In the final phase of this operation a bubble of expansive gas (SF6 or C3F8) is injected into the eye to push recovering parts of the retina together. Positioning the head correctly for a period of several days or even weeks is then crucial for achieving optimal treatment results. The designed head-mounted intelligent device continuously monitors the head position and immediately warns the patient whenever detected position is out of the desired boundaries set by the clinician. The position of the head is described by the angle of tilt in all axes. As asensing element a 3D MEMS accelerometer is utilized. Digital signal processing is used for noise suppression, tilt angle calculation and for calibrating the sensor. Position data is stored into a built-in flash memory in regular intervals
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F08%2F1373" target="_blank" >GA102/08/1373: Monitorování polohy hlavy pacienta</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IFMBE Proceedings
ISBN
978-3-540-89207-6
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
Springer
Místo vydání
Antwerp, Belgium
Místo konání akce
Antverpy
Datum konání akce
23. 11. 2008
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—