Real-time measurement of air ion spectrum using gerdien tube with segmented inner electrode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F09%3APU80914" target="_blank" >RIV/00216305:26220/09:PU80914 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Real-time measurement of air ion spectrum using gerdien tube with segmented inner electrode
Popis výsledku v původním jazyce
The gerdien tube measurement method is useful to measure spectrum of air ions. In a standard type of the gerdien tube with non-segmented electrode we must change voltage in the time. The disadvantage of this method is impossibility of real time measurement because the measurement is very time-consuming. Using the segmented inner electrode, it is possible to measure the air ions spectrum without necessity of the time variant voltage between the electrodes. This paper deals with a mathematic analyze and numerical modeling of ions trajectories in the gerdien tube with the segmented inner electrode. The method of computing of the distribution of air ions mobility from currents measured on each of electrodes will be shown.
Název v anglickém jazyce
Real-time measurement of air ion spectrum using gerdien tube with segmented inner electrode
Popis výsledku anglicky
The gerdien tube measurement method is useful to measure spectrum of air ions. In a standard type of the gerdien tube with non-segmented electrode we must change voltage in the time. The disadvantage of this method is impossibility of real time measurement because the measurement is very time-consuming. Using the segmented inner electrode, it is possible to measure the air ions spectrum without necessity of the time variant voltage between the electrodes. This paper deals with a mathematic analyze and numerical modeling of ions trajectories in the gerdien tube with the segmented inner electrode. The method of computing of the distribution of air ions mobility from currents measured on each of electrodes will be shown.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Progress in Electromagnetics Research Symposium (PIERS 2009)
ISBN
978-1-934142-08-0
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
The Electromagnetic Academy
Místo vydání
Cambridge
Místo konání akce
Moscow
Datum konání akce
18. 8. 2009
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—