THICK FILM RESISTORS NDT BY ELECTRO-ULTRASONIC SPECTROSCOPY
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F09%3APU83436" target="_blank" >RIV/00216305:26220/09:PU83436 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
THICK FILM RESISTORS NDT BY ELECTRO-ULTRASONIC SPECTROSCOPY
Popis výsledku v původním jazyce
The non-linear electro-ultrasonic spectroscopy was used as a non-destructive testing method for the polymer based and cermet thick film resistors evaluation. We carried out the correlation between this method and standard testing methods as noise spectroscopy and the third harmonic voltage measurements. The measuring set-up with the ultrasonic transducer working on the frequency range 10 kHz to 1 MHz was designed and realized. Proposed method is exploiting two different signal sources - ultrasonic waveand alternating electric current. Mechanical vibrations affect the defects in the sample structure and it influences the electric charge transport through the measured structure. Resulting information is measured on the differential frequency given by the superposition or subtraction of exciting signals frequencies. Low-pass filter with limit frequency 5 kHz was used for the suppression of exciting signals amplitudes. Measured sample together with the ultrasonic transducer creates the re
Název v anglickém jazyce
THICK FILM RESISTORS NDT BY ELECTRO-ULTRASONIC SPECTROSCOPY
Popis výsledku anglicky
The non-linear electro-ultrasonic spectroscopy was used as a non-destructive testing method for the polymer based and cermet thick film resistors evaluation. We carried out the correlation between this method and standard testing methods as noise spectroscopy and the third harmonic voltage measurements. The measuring set-up with the ultrasonic transducer working on the frequency range 10 kHz to 1 MHz was designed and realized. Proposed method is exploiting two different signal sources - ultrasonic waveand alternating electric current. Mechanical vibrations affect the defects in the sample structure and it influences the electric charge transport through the measured structure. Resulting information is measured on the differential frequency given by the superposition or subtraction of exciting signals frequencies. Low-pass filter with limit frequency 5 kHz was used for the suppression of exciting signals amplitudes. Measured sample together with the ultrasonic transducer creates the re
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GD102%2F09%2FH074" target="_blank" >GD102/09/H074: Diagnostika defektů v materiálech za použití nejnovějších defektoskopických metod</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Vth workshop NDT in progress
ISBN
978-80-214-3968-9
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
Neuveden
Místo vydání
Neuveden
Místo konání akce
Průhonice
Datum konání akce
12. 10. 2009
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—