Electro Ultrasonic Spectroscopy of Cermet Thick Films
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F09%3APU81550" target="_blank" >RIV/00216305:26220/09:PU81550 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electro Ultrasonic Spectroscopy of Cermet Thick Films
Popis výsledku v původním jazyce
The electro-ultrasonic spectroscopy is non-destructive testing method for cermet resistors. This method can be used as a diagnostic tool for the quality and reliability assessment. AC current varying with frequency fE and the ultrasonic signal varying with frequency fU are applied on the conducting sample and a new intermodulation signal on the frequency fm given by the superposition or subtraction of exciting frequencies is measured on the sample. The sample resistance is influenced by the ultrasonic signal. The ultrasonic signal changes the contact area between the conducting grains in the sample structure and then resistance is modulated by the frequency of ultrasonic excitation. The electrical charge and also the electrical current flowing throughthe sample structure are conserved. In case the contact area between the conducting grains is changing then the current density is changed. This leads to the resistivity change of measured structure. We suppose that for the sample with mo
Název v anglickém jazyce
Electro Ultrasonic Spectroscopy of Cermet Thick Films
Popis výsledku anglicky
The electro-ultrasonic spectroscopy is non-destructive testing method for cermet resistors. This method can be used as a diagnostic tool for the quality and reliability assessment. AC current varying with frequency fE and the ultrasonic signal varying with frequency fU are applied on the conducting sample and a new intermodulation signal on the frequency fm given by the superposition or subtraction of exciting frequencies is measured on the sample. The sample resistance is influenced by the ultrasonic signal. The ultrasonic signal changes the contact area between the conducting grains in the sample structure and then resistance is modulated by the frequency of ultrasonic excitation. The electrical charge and also the electrical current flowing throughthe sample structure are conserved. In case the contact area between the conducting grains is changing then the current density is changed. This leads to the resistivity change of measured structure. We suppose that for the sample with mo
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BE - Teoretická fyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
32nd International Spring Seminar on Electronics Technology
ISBN
978-1-4244-4260-7
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
—
Název nakladatele
Neuveden
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
13. 5. 2009
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—