Electro Ultrasonic Spectroscopy of Magnesium Composites
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F10%3APU87347" target="_blank" >RIV/00216305:26220/10:PU87347 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electro Ultrasonic Spectroscopy of Magnesium Composites
Popis výsledku v původním jazyce
The electro-ultrasonic spectroscopy was used as a non-destructive testing method for the magnesium composites evaluation. AC current varying with frequency fE and the ultrasonic signal varying with frequency fU are applied on the conducting sample and anew intermodulation signal on the frequency fm given by the superposition or subtraction of exciting frequencies is measured on the sample. We have measured on intermodulation frequency fm = fE - fU. This method can be used as a diagnostic tool for the quality and reliability assessment. The sample resistance is influenced by the ultrasonic signal. The ultrasonic signal changes the contact area between the conducting grains in the sample structure and then resistance is modulated by the frequency of ultrasonic excitation. The electrical charge and also the electrical current flowing through the sample structure are conserved. In case the contact area between the conducting grains is changing then the current density is changed. This lea
Název v anglickém jazyce
Electro Ultrasonic Spectroscopy of Magnesium Composites
Popis výsledku anglicky
The electro-ultrasonic spectroscopy was used as a non-destructive testing method for the magnesium composites evaluation. AC current varying with frequency fE and the ultrasonic signal varying with frequency fU are applied on the conducting sample and anew intermodulation signal on the frequency fm given by the superposition or subtraction of exciting frequencies is measured on the sample. We have measured on intermodulation frequency fm = fE - fU. This method can be used as a diagnostic tool for the quality and reliability assessment. The sample resistance is influenced by the ultrasonic signal. The ultrasonic signal changes the contact area between the conducting grains in the sample structure and then resistance is modulated by the frequency of ultrasonic excitation. The electrical charge and also the electrical current flowing through the sample structure are conserved. In case the contact area between the conducting grains is changing then the current density is changed. This lea
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BE - Teoretická fyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Jemná mechanika a optika
ISSN
0447-6441
e-ISSN
—
Svazek periodika
55
Číslo periodika v rámci svazku
5/2010
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
3
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—