Popis výsledku v původním jazyce
This article deals with three-dimensional reconstruction methods of nuclear magnetic resonance images. The testing images were observed by tomography with basic magnetic field of 4.7T at the Institute of Scientific Instruments (Academy of Sciences of theCzech Republic). 10 slices of the testing phantom were acquired. The methods were proposed with the aim of getting utmost information about the shape of the testing phantom. One possible way is to increase the number of the sensed slices, but it impliesdecreasing of the signal to noise ratio. The second approach is finding the compromise between the effective count of slices and the following interpolation of other slices between the sensed ones. The both approaches were compared. The resultant imageswere segmented by the active contour methods which are based on partial differential equations solution [1, 2]. The advantage of these methods is that the images may not be preprocessed before segmentation. The appropriate segmented slic
Název v anglickém jazyce
3D reconstruction in magnetic resonance imaging
Popis výsledku anglicky
This article deals with three-dimensional reconstruction methods of nuclear magnetic resonance images. The testing images were observed by tomography with basic magnetic field of 4.7T at the Institute of Scientific Instruments (Academy of Sciences of theCzech Republic). 10 slices of the testing phantom were acquired. The methods were proposed with the aim of getting utmost information about the shape of the testing phantom. One possible way is to increase the number of the sensed slices, but it impliesdecreasing of the signal to noise ratio. The second approach is finding the compromise between the effective count of slices and the following interpolation of other slices between the sensed ones. The both approaches were compared. The resultant imageswere segmented by the active contour methods which are based on partial differential equations solution [1, 2]. The advantage of these methods is that the images may not be preprocessed before segmentation. The appropriate segmented slic
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F09%2F0314" target="_blank" >GA102/09/0314: Studium vlastností metamateriálů a mikrovlnných struktur s využitím šumové spektroskopie a magnetické rezonance</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Progress In Electromagnetics
ISSN
1559-9450
e-ISSN
—
Svazek periodika
2010
Číslo periodika v rámci svazku
2010
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
4
Strana od-do
1043-1046
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—