Interpolation of 3D Magnetic Resonance Data
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F11%3APU91605" target="_blank" >RIV/00216305:26220/11:PU91605 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Interpolation of 3D Magnetic Resonance Data
Popis výsledku v původním jazyce
This article deals with three-dimensional reconstruction methods of nuclear magnetic resonance images. The testing images were observed by tomography with basic magnetic field of 4.7T at the Institute of Scientific Instruments (Academy of Sciences of theCzech Republic). The 20 slices of the test phantom were acquired. Two methods were found with the aim of getting utmost information about the shape of the testing phantom. One possible way is to increase the count of the sensed slices, but it implies decreasing of the signal to noise ratio. The second approach is finding the compromise between the effective count of slices and the following interpolation of other slices between the sensed ones. The both approaches were compared. Only 10 slices were used to compute the in-between others. It is better to use this approach because the computed slices can be compared with the real slices obtained by MR tomography. The results are described in the article. The images were interpolated in or
Název v anglickém jazyce
Interpolation of 3D Magnetic Resonance Data
Popis výsledku anglicky
This article deals with three-dimensional reconstruction methods of nuclear magnetic resonance images. The testing images were observed by tomography with basic magnetic field of 4.7T at the Institute of Scientific Instruments (Academy of Sciences of theCzech Republic). The 20 slices of the test phantom were acquired. Two methods were found with the aim of getting utmost information about the shape of the testing phantom. One possible way is to increase the count of the sensed slices, but it implies decreasing of the signal to noise ratio. The second approach is finding the compromise between the effective count of slices and the following interpolation of other slices between the sensed ones. The both approaches were compared. Only 10 slices were used to compute the in-between others. It is better to use this approach because the computed slices can be compared with the real slices obtained by MR tomography. The results are described in the article. The images were interpolated in or
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP102%2F11%2F0318" target="_blank" >GAP102/11/0318: Analýza metabolizmu a lokalizace změn kostní tkáně čelisti pomocí MR zobrazovacích technik</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Progress In Electromagnetics
ISSN
1559-9450
e-ISSN
—
Svazek periodika
2011
Číslo periodika v rámci svazku
2011
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
4
Strana od-do
639-642
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—