A comparison of test methods for the measurement of hydrogen sensor response and recovery times
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F10%3APU90245" target="_blank" >RIV/00216305:26220/10:PU90245 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A comparison of test methods for the measurement of hydrogen sensor response and recovery times
Popis výsledku v původním jazyce
Response time is a critically important property of hydrogen safety sensors. Recovery times are less important from a safety perspective, but are often quoted as an indication of the speed of operation of a sensor. However, the measured values depend highly on the method used to evaluate them. The purpose of this work is to assess the suitability of different methods, both flow and diffusion-based, for the measurement of sensor response and recovery times. Four methods have been tested in terms of theirrepeatability and practicality of execution, as well as the accuracy of their results compared to the manufacturer's specifications. It was found that each method has its own advantages and limitations. For the measurement of response times, a diffusion-based method was found to give the shortest and most precise values and is therefore recommended. However, the flow-based method was found to be the most convenient experimentally and is the only method that is suitable for the measureme
Název v anglickém jazyce
A comparison of test methods for the measurement of hydrogen sensor response and recovery times
Popis výsledku anglicky
Response time is a critically important property of hydrogen safety sensors. Recovery times are less important from a safety perspective, but are often quoted as an indication of the speed of operation of a sensor. However, the measured values depend highly on the method used to evaluate them. The purpose of this work is to assess the suitability of different methods, both flow and diffusion-based, for the measurement of sensor response and recovery times. Four methods have been tested in terms of theirrepeatability and practicality of execution, as well as the accuracy of their results compared to the manufacturer's specifications. It was found that each method has its own advantages and limitations. For the measurement of response times, a diffusion-based method was found to give the shortest and most precise values and is therefore recommended. However, the flow-based method was found to be the most convenient experimentally and is the only method that is suitable for the measureme
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY
ISSN
0360-3199
e-ISSN
—
Svazek periodika
35 (2010)
Číslo periodika v rámci svazku
14
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
12
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—