A 3D Magnetic Measurement for S/N < 0.01
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F11%3APU93760" target="_blank" >RIV/00216305:26220/11:PU93760 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A 3D Magnetic Measurement for S/N < 0.01
Popis výsledku v původním jazyce
The authors describe the process of developing a 3D meter designed for magnetic field mapping in MR Image Reconstruction (MREIT). As the anticipated application of MREIT involves the factor of an environment with strong electromagnetic disturbance, it isnecessary to use a measurement method insensitive to such conditions. The most significant spurious signals affecting the process of measurement come from the supply mains and switched supply sources. In order to suppress these influences, the authors utilize the principle of synchronous detection in a lock-in amplifier; the amplifier facilitates the suppression of these spurious disturbing signals and enables the selection of the required ones. In the designed 3D magnetic field meter, Hall probes areused for the measurement of magnetic induction. At the beginning of the measurement, the measuring device automatically corrects the reference signal phase shift for the maximum amplitude of the output direct voltage; also, the influence
Název v anglickém jazyce
A 3D Magnetic Measurement for S/N < 0.01
Popis výsledku anglicky
The authors describe the process of developing a 3D meter designed for magnetic field mapping in MR Image Reconstruction (MREIT). As the anticipated application of MREIT involves the factor of an environment with strong electromagnetic disturbance, it isnecessary to use a measurement method insensitive to such conditions. The most significant spurious signals affecting the process of measurement come from the supply mains and switched supply sources. In order to suppress these influences, the authors utilize the principle of synchronous detection in a lock-in amplifier; the amplifier facilitates the suppression of these spurious disturbing signals and enables the selection of the required ones. In the designed 3D magnetic field meter, Hall probes areused for the measurement of magnetic induction. At the beginning of the measurement, the measuring device automatically corrects the reference signal phase shift for the maximum amplitude of the output direct voltage; also, the influence
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Progress In Electromagnetics
ISSN
1559-9450
e-ISSN
—
Svazek periodika
2011
Číslo periodika v rámci svazku
2011
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
981-985
Kód UT WoS článku
—