Limits to the Measurement of the Magnetic Susceptibility Using NMR Method
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F11%3APU93766" target="_blank" >RIV/00216305:26220/11:PU93766 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Limits to the Measurement of the Magnetic Susceptibility Using NMR Method
Popis výsledku v původním jazyce
The paper deals with modeling of the distribution of the magnetic field close to the non-ferromagnetic substances. Non-ferromagnetic cylinders were placed in the center of the cube shaped static magnetic field B0=4.7 T. Material of the specimen react with the static magnetic field and create a local changes of this field close to the specimen surface. Changes of the static magnetic field hold the possibilities to calculate the magnetic susceptibility of used material. In this article will be discuss what under conditions is possible to use 1D and 2D method. Model results enable to set up the limits of used method. Consequently, the influence of the relation between length and diameter of the specimen on the accuracy of the magnetic susceptibility calculation is examined. As a specimen materials were used the varied size aluminum, platinum, bismuth and copper cylinders.
Název v anglickém jazyce
Limits to the Measurement of the Magnetic Susceptibility Using NMR Method
Popis výsledku anglicky
The paper deals with modeling of the distribution of the magnetic field close to the non-ferromagnetic substances. Non-ferromagnetic cylinders were placed in the center of the cube shaped static magnetic field B0=4.7 T. Material of the specimen react with the static magnetic field and create a local changes of this field close to the specimen surface. Changes of the static magnetic field hold the possibilities to calculate the magnetic susceptibility of used material. In this article will be discuss what under conditions is possible to use 1D and 2D method. Model results enable to set up the limits of used method. Consequently, the influence of the relation between length and diameter of the specimen on the accuracy of the magnetic susceptibility calculation is examined. As a specimen materials were used the varied size aluminum, platinum, bismuth and copper cylinders.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Progress In Electromagnetics
ISSN
1559-9450
e-ISSN
—
Svazek periodika
2011
Číslo periodika v rámci svazku
2011
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
4
Strana od-do
76-79
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—