Visualization of plant fibres via diffusion tensor imaging
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F11%3APU93772" target="_blank" >RIV/00216305:26220/11:PU93772 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Visualization of plant fibres via diffusion tensor imaging
Popis výsledku v původním jazyce
The paper deals with MR imaging of plant fibres via Diffusion weighted imaging (DWI) and Diffusion tensor imaging (DTI). Imaging plant fibres helps to better understand the process of nourishing the plants, and also to come to know the internal structureof plants without damaging them. To measure diffusion in the plant specimen, the well-known NMR method was used, currently referred to as the Pulsed field gradient spin-echo (PFGSE). Experimental measurement was conducted on an MR tomograph system withthe gradient field B0 = 4.7 T. Onion and dill were used as specimens to be measured. The values obtained by the PFGSE method were used to calculate diffusion weighted images (DWI). The measurement of diffusion weighted images was performed in 6 directions of the gradients (x, y, z, xy, xz, yz) and the data obtained served to calculate the DTI image of the specimen being measured.
Název v anglickém jazyce
Visualization of plant fibres via diffusion tensor imaging
Popis výsledku anglicky
The paper deals with MR imaging of plant fibres via Diffusion weighted imaging (DWI) and Diffusion tensor imaging (DTI). Imaging plant fibres helps to better understand the process of nourishing the plants, and also to come to know the internal structureof plants without damaging them. To measure diffusion in the plant specimen, the well-known NMR method was used, currently referred to as the Pulsed field gradient spin-echo (PFGSE). Experimental measurement was conducted on an MR tomograph system withthe gradient field B0 = 4.7 T. Onion and dill were used as specimens to be measured. The values obtained by the PFGSE method were used to calculate diffusion weighted images (DWI). The measurement of diffusion weighted images was performed in 6 directions of the gradients (x, y, z, xy, xz, yz) and the data obtained served to calculate the DTI image of the specimen being measured.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP102%2F11%2F0318" target="_blank" >GAP102/11/0318: Analýza metabolizmu a lokalizace změn kostní tkáně čelisti pomocí MR zobrazovacích technik</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Progress In Electromagnetics
ISSN
1559-9450
e-ISSN
—
Svazek periodika
2011
Číslo periodika v rámci svazku
2011
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
4
Strana od-do
1013-1016
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—