Visualization of Plant Fibres via Difusion Tensor Imaging
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F11%3A00367356" target="_blank" >RIV/68081731:_____/11:00367356 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.2529/PIERS110217033410" target="_blank" >http://dx.doi.org/10.2529/PIERS110217033410</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2529/PIERS110217033410" target="_blank" >10.2529/PIERS110217033410</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Visualization of Plant Fibres via Difusion Tensor Imaging
Popis výsledku v původním jazyce
The paper deals with MR imaging of plant fibres via Difusion weighted imaging (DWI) and Difusion tensor imaging (DTI). Imaging plant fibres helps to better understand the process of nourishing the plants, and also to come to know the internal structure of plants without damaging them. To measure difusion in the plant specimen, the well-known NMR method was used, currently referred to as the Pulsed field gradient spin-echo (PFGSE). Experimental measurement was conducted on an MR tomograph system with thegradient field B0 = 4:7 T. Onion and dill were used as specimens to be measured. The values obtained by the PFGSE method were used to calculate difusion weighted images (DWI). The measurement of difusion weighted images was performed in 6 directions ofthe gradients (x, y, z, xy, xz, yz) and the data obtained served to calculate the DTI image of the specimen being measured.
Název v anglickém jazyce
Visualization of Plant Fibres via Difusion Tensor Imaging
Popis výsledku anglicky
The paper deals with MR imaging of plant fibres via Difusion weighted imaging (DWI) and Difusion tensor imaging (DTI). Imaging plant fibres helps to better understand the process of nourishing the plants, and also to come to know the internal structure of plants without damaging them. To measure difusion in the plant specimen, the well-known NMR method was used, currently referred to as the Pulsed field gradient spin-echo (PFGSE). Experimental measurement was conducted on an MR tomograph system with thegradient field B0 = 4:7 T. Onion and dill were used as specimens to be measured. The values obtained by the PFGSE method were used to calculate difusion weighted images (DWI). The measurement of difusion weighted images was performed in 6 directions ofthe gradients (x, y, z, xy, xz, yz) and the data obtained served to calculate the DTI image of the specimen being measured.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP102%2F11%2F0318" target="_blank" >GAP102/11/0318: Analýza metabolizmu a lokalizace změn kostní tkáně čelisti pomocí MR zobrazovacích technik</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
PIERS Online
ISSN
1931-7360
e-ISSN
—
Svazek periodika
7
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
4
Strana od-do
543-546
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—