Measurement of DWI and DTI Images of Isotropic and Anisotropic Materials by Using NMR Methods
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F12%3APU97726" target="_blank" >RIV/00216305:26220/12:PU97726 - isvavai.cz</a>
Výsledek na webu
<a href="http://piers.org/piersproceedings/download.php?file=cGllcnMyMDEyS3VhbGFMdW1wdXJ8MVA3XzAzNjkucGRmfDExMDkyMDA2NDcxNA==" target="_blank" >http://piers.org/piersproceedings/download.php?file=cGllcnMyMDEyS3VhbGFMdW1wdXJ8MVA3XzAzNjkucGRmfDExMDkyMDA2NDcxNA==</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement of DWI and DTI Images of Isotropic and Anisotropic Materials by Using NMR Methods
Popis výsledku v původním jazyce
The paper deals with measurement of Diffusion Weighted Imaging (DWI) and Diffusion Tensor Imaging (DTI) images of images of isotropic and anisotropic materials by using NMR methods. We studied differences between the tensor determined from the sample ofan isotropic and an anisotropic material; we compared the results with the theoretical knowledge. As a sample of isotropic material, we used a physiological solution (saline). As a sample of anisotropic material we used plants-cabbage. For measurement ofDWI and DTI images, we applied a widely used method of measuring | the Pulse Filed Gradient Spin Echo (PFGSE). The experiments were carried out on an MR tomograph system 4.7 T/120mm (i.e., 200MHz for 1H nuclei). Actively shielded gradient coils yield amaximum gradient field magnitude of 180 mT/m. The data measured were processed in the MAREVISI and MATLAB programs.
Název v anglickém jazyce
Measurement of DWI and DTI Images of Isotropic and Anisotropic Materials by Using NMR Methods
Popis výsledku anglicky
The paper deals with measurement of Diffusion Weighted Imaging (DWI) and Diffusion Tensor Imaging (DTI) images of images of isotropic and anisotropic materials by using NMR methods. We studied differences between the tensor determined from the sample ofan isotropic and an anisotropic material; we compared the results with the theoretical knowledge. As a sample of isotropic material, we used a physiological solution (saline). As a sample of anisotropic material we used plants-cabbage. For measurement ofDWI and DTI images, we applied a widely used method of measuring | the Pulse Filed Gradient Spin Echo (PFGSE). The experiments were carried out on an MR tomograph system 4.7 T/120mm (i.e., 200MHz for 1H nuclei). Actively shielded gradient coils yield amaximum gradient field magnitude of 180 mT/m. The data measured were processed in the MAREVISI and MATLAB programs.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP102%2F11%2F0318" target="_blank" >GAP102/11/0318: Analýza metabolizmu a lokalizace změn kostní tkáně čelisti pomocí MR zobrazovacích technik</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Progress in Electromagnetics Research Symposium Proceedings, KL, Malaysia
ISBN
978-1-934142-12-7
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
369-373
Název nakladatele
Neuveden
Místo vydání
Kuala Lumpur
Místo konání akce
Kuala Lumpur
Datum konání akce
27. 3. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—