Limiting Effects in the Application of Inductive Sensors for Measuring of Non-harmonic High-level Current Pulses
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F12%3APU98039" target="_blank" >RIV/00216305:26220/12:PU98039 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Limiting Effects in the Application of Inductive Sensors for Measuring of Non-harmonic High-level Current Pulses
Popis výsledku v původním jazyce
This article deals with description of limiting effects occurring by measurement of non-harmonical high-level current pulses by means of inductive sensors. These effects will be described for the case of Rogowski coil application in current pulses measurement. The first is a fact that the sensor must be considered as a circuit with distributed parameters. For measuring of non-harmonic waveforms is necessary to ensure the Heaviside's condition for distortionless transmission line. The second factor is the Gibbs's effect which causes overshoots on the edges of a rectangular pulse. The third factor is the influence of wire position in the sensor on the character of output waveform. All of these factors which have been mentioned above cause a serious limitation of induction sensor application for non-harmonic current pulses measurement. Special precautions have to be ensured in order to attain of distortion-free measurement. The influence of precaution violation on the measured waveform wi
Název v anglickém jazyce
Limiting Effects in the Application of Inductive Sensors for Measuring of Non-harmonic High-level Current Pulses
Popis výsledku anglicky
This article deals with description of limiting effects occurring by measurement of non-harmonical high-level current pulses by means of inductive sensors. These effects will be described for the case of Rogowski coil application in current pulses measurement. The first is a fact that the sensor must be considered as a circuit with distributed parameters. For measuring of non-harmonic waveforms is necessary to ensure the Heaviside's condition for distortionless transmission line. The second factor is the Gibbs's effect which causes overshoots on the edges of a rectangular pulse. The third factor is the influence of wire position in the sensor on the character of output waveform. All of these factors which have been mentioned above cause a serious limitation of induction sensor application for non-harmonic current pulses measurement. Special precautions have to be ensured in order to attain of distortion-free measurement. The influence of precaution violation on the measured waveform wi
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/FR-TI1%2F001" target="_blank" >FR-TI1/001: Výzkum a vývoj detekce výbojové aktivity ve výkonových olejových transformátorech</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Progress in Electromagnetics Research Symposium Proceedings, KL, Malaysia
ISBN
978-1-934142-12-7
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
353-356
Název nakladatele
Neuveden
Místo vydání
Neuveden
Místo konání akce
Kuala Lumpur
Datum konání akce
27. 3. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—