Test Frequency Selection for Overdetermined System of Fault Equations
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F13%3APU103485" target="_blank" >RIV/00216305:26220/13:PU103485 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Test Frequency Selection for Overdetermined System of Fault Equations
Popis výsledku v původním jazyce
The paper deals with a multifrequency parametric fault diagnosis of linear analog circuits. The method can estimate the actual values of some network parameters. The components whose parameters are outside allowed tolerance intervals are classified as faulty. The parameter estimation process based on square system of equations uses measurements at several test frequencies while the rest of the frequency band may not be taken into account. An overdetermined system of fault equations can significantly reduce the error of solution. However, basic methods for test frequency selection usually find test frequencies which are distributed very close to each other which is not optimal in terms of an overdetermined system. For this reason, a new control mechanism based on a penalty function, which gives more regularly distributed test frequencies over the whole frequency band, is described in this paper. The proposed procedure is demonstrated on a test frequency selection for an EMI filter.
Název v anglickém jazyce
Test Frequency Selection for Overdetermined System of Fault Equations
Popis výsledku anglicky
The paper deals with a multifrequency parametric fault diagnosis of linear analog circuits. The method can estimate the actual values of some network parameters. The components whose parameters are outside allowed tolerance intervals are classified as faulty. The parameter estimation process based on square system of equations uses measurements at several test frequencies while the rest of the frequency band may not be taken into account. An overdetermined system of fault equations can significantly reduce the error of solution. However, basic methods for test frequency selection usually find test frequencies which are distributed very close to each other which is not optimal in terms of an overdetermined system. For this reason, a new control mechanism based on a penalty function, which gives more regularly distributed test frequencies over the whole frequency band, is described in this paper. The proposed procedure is demonstrated on a test frequency selection for an EMI filter.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proccedings of the 23rd International Conference Radioelektronika 2013.
ISBN
978-1-4673-5517-9
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
115-118
Název nakladatele
Neuveden
Místo vydání
University of Pardubice, Pardubice, Czech Republ
Místo konání akce
Pardubice
Datum konání akce
16. 4. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000326877900020